Data Setting and Monitoring
1,2,3...
Protect Setting (Mode 4)
1,2,3...
20
How to Clear Data
1. Follow (1) to (3) of the above procedure to cause the items that are to be
cleared to start blinking.
2. Press the Clear Key twice. When it is pressed the first time, all of the items
to be cleared will start blinking.
When it is pressed the second time, all of the ON/OFF angle data will be
cleared for the items that are blinking. If CAM no. "1" is blinking, for exam-
ple, then the ON/OFF angle data for steps 1 to 7 for cam output no. 1 will
be cleared.
To cancel a clearing operation, press any other key instead of pressing the
Clear Key the second time.
1. Set the RUN/PRG selector switch to PRG.
If PRG is already selected, then proceed directly to (2).
2. Press the Return Key, the Up Key, or the Down Key to cause the Mode 4
indicator to blink.
Press the Return Key, the Up Key, or the Down Key.
The MODE indicator will blink.
Press either the Up Key or the Down Key until "4" is displayed.
Mode 4 cannot be selected if pin 2 of the rear panel DIP switch is ON (i.e.,
if protection is not permitted).
3. Press the Return Key to cause the bank number to blink.
4. Use the Up Key or the Down Key to display the bank number for which pro-
tection is to be set or cleared.
5. Press the Return Key to cause the data display to blink.
For each bank number, use the Up and Down Keys to select either "+- "
(protection set) or "
enter the selection.
When changing bank numbers, press the Reverse Key to return to the
blinking bank number display.
To set or clear protection for cam numbers, proceed to (6).
6. Press the Return Key to cause the cam number to blink.
7. Use the Up Key or the Down Key to display the cam number for which pro-
tection is to be set or cleared.
8. Press the Return Key to cause the data display to blink.
--- : Not protected
pr% : Protected
Bank no.
Mode no.
" (protection not set). Then press the Return Key to