Table 17. Shdsl-A And Shdsl-B Alarm Types - ADC PG-FlexPlus ARL-942 Manual

Table of Contents

Advertisement

SCP-ARL942-010-02H
SHDSL Alarms
SHDSL LOSW(1)
SHDSL ES 15 Min(2)
SHDSL ES 24 Hour(2)
SHDSL UAS 15 Min(3)
SHDSL UAS 24 Hour(3) CR, MJ, MN, NA, NR
SHDSL Low Margin
SHDSL Low Bandwidth
SHDSL Payload Sync
Power Feed Open
Power Feed Short
Power Ground Fault
(1) SHDSL LOSW: A condition that generally indicates the loop is down, thus data cannot be transmitted. The
ARL-942 uses this parameter to derive UAS performance
(2) SHDSL ES: Intervals during which at least one CRC is detected at the incoming SHDSL port.
(3) SHDSL UAS: An interval of 1 second during which a loop is down.
72

Table 17. SHDSL-A and SHDSL-B Alarm Types

Value
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
Description
SHDSL link has lost
synchronization
Active if the 15 minute ES
count equals or exceeds the
threshold in the current 15
minute interval
Active if the count equals or
exceeds the threshold in the
current 24 hour
interval
Active if the count equals or
exceeds the threshold in the
current 15 minute
interval
Active if the count equals or
exceeds the threshold in the
current 24 hour
interval
Active if the margin equals or
drops below the threshold
Active if the SHDSL band-
width is not sufficient to sup-
port the services provided
by the RT
Active if there is a problem
detected in the SHDSL
overhead channel
Open circuit detected on the
SHDSL span
Short circuit detected on the
SHDSL span
Ground fault condition
detected on the SHDSL span
statistics.
January 6, 2003
COLU Type
RT Type
Default
Default
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
NA
NA
MN
MN
MN
MN
MN
ADC Telecommunications, Inc.