SCP-ARL942-010-02H
Settings
Reported
CR – Critical
MJ – Major
MN – Minor
NA – Not Alarmed
NR – Not Reported
Alarm
COLU-RT A Mismatch
No RT A software
COLU RT B Mismatch
No RT B software
MUX Payload Error
EEPROM Failure
66
Table 14. Alarm Types Reported
Alarm LED
Lit
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Table 15. System Alarms Types
Value
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
Main Shelf
Summary
History Updated
Yes
Yes
Yes
No
No
Description
Incompatible RT A unit has been
installed
RT A has no application software
and is awaiting software download
Incompatible RT B unit has been
installed
RT B has no application software
and is awaiting software download
Parity error detected between MUX
and COLU. An alarm is generated
and all circuits are placed in a trunk-
conditioned state.
EEPROM (nonvolatile memory) has
failed
ADC Telecommunications, Inc.
January 6, 2003
SNMP Trap
Message
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Default
MN
MN
MN
MN
MN
MN
Need help?
Do you have a question about the PG-FlexPlus ARL-942 and is the answer not in the manual?
Questions and answers