Circontrol eVolve Smart Series User Manual page 51

Hide thumbs Also See for eVolve Smart Series:
Table of Contents

Advertisement

Value
ID
Cache max. size
Use OCPP time
synchronization
Energy for Start/
Stop transaction
Energy for
MeterValues
User confirmation
required on remote
start
Charge Point identifier
Maximum size of the Authorization Cache, that autonomously
maintains a record of previously presented identifiers that have
been successfully authorized by the Central System.
It can be viewed accessing to the following URL:
http://<IP>:8080/services/cmd/dump_cache.xml
YES: Synchronization of date and time -> Enabled.
NO: Synchronization of date and time -> Disabled.
*NOTE: Date and Time is sent from backend on each heartbeat
response.
PARTIAL: Consumed value of energy by the vehicle sent between
start and stop.
TOTAL: actual count of the total accumulated energy meter sent
between start and stop.
PARTIAL: Sends partial energy consumption while vehicle is
charging.
TOTAL: sends the actual count of the total accumulated energy
meter.
ON: user confirmation needed to proceed with a remote start (i.e.
touch the screen)
OFF: user confirmation NOT needed to proceed with a remote
start