Query Minimum Track Rate - Globalstar ST100 User Manual

Hide thumbs Also See for ST100:
Table of Contents

Advertisement

8545-0194-01 v1.0
BYTE
BITS
0
0 - 7
1
0 - 7
2
0 - 7
3-4
0 - 15
5-6
0 - 15
Response: AA 05 84 <CRC>
NOTE: If a track mode (0x30, 0x34, or 0x35) is already active, this command will be NAK'd if a value of greater than the track
already running is sent.
The purpose of this command is to allow a VAR to limit the minimum track interval that a customer might set so as to not over-
discharge the battery and solar charging system chosen for the particular application.

4.2.2.28. "Query Minimum Track Rate"

BYTE
BITS
0
0 - 7
1
0 - 7
2
0 - 7
3-4
0 - 15
BYTE
BITS
0
0 - 7
1
0 - 7
2
0 - 7
3-4
0 - 15
5-6
0 - 15
ST100 User Manual v1
SET MINIMUM TRACK RATE COMMAND
PARAMETER
Leader
Length
Command Code
Rate
CRC
QUERY MINIMUM TRACK RATE
PARAMETER
Leader
Length
Command Code
CRC
QUERY MINIMUM TRACK RATE RESPONSE
PARAMETER
Leader
Length
Command Code
Rate
CRC
Confidential & Proprietary Information
DESCRIPTION
Always a value of 0xAA
0x07
0x84 = Set minimum track rate command
Rate in minutes, MSB first
DESCRIPTION
Always a value of 0xAA
0x05
0x85 = "Query minimum track rate"
Will contain the CRC
DESCRIPTION
Always a value of 0xAA
0x07
0x85 = Query minimum track rate
Rate in minutes, MSB first
50

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents