Transmitter Statistics Query; Set Accelerometer On/Off Command - Globalstar ST100 User Manual

Hide thumbs Also See for ST100:
Table of Contents

Advertisement

8545-0194-01 v1.0
4.2.2.20. "Transmitter Statistics" query.
BYTE
BITS
0
0 - 7
1
0 - 7
2
0 - 7
3-4
0 - 15
BYTE
BITS
0
0 - 7
1
0 - 7
2
0 - 7
3
0 - 7
4-5
0 - 15
Total messages in mode
6-7
0 - 15
Total Packets Transmitted
8-9
0 - 15
10-11
0 - 15
4.2.2.21. "Set Accelerometer On/Off" Command.
This command is intended to be used ONLY in units where the hardware has been configured to connect the accelerometer to
the Nordic processor. If a Motion Activated Track is running, that command will be NAK'd.
BYTE
BITS
0
0 - 7
1
0 - 7
2
0 - 7
3
0 - 7
4-5
0 - 15
ST100 User Manual v1

TRANSMITTER STATISTICS QUERY

PARAMETER
Leader
Length
Command Code
CRC
TRANSMITTER STATISTICS RESPONSE
PARAMETER
Leader
Length
Command Code
Reset Flag
Total TX failures
CRC

SET ACCELEROMETER ON/OFF COMMAND

PARAMETER
Leader
Length
Command Code
On or off
CRC
Confidential & Proprietary Information
DESCRIPTION
Always a value of 0xAA
0x3B = Transmitter Statistics Query
0x3B = Transmitter Statistics Query
0x00 = Device has not reset since the last time this query was issued
0x01 = Device has reset since the last time this query was issued
Total messages transmitted in the current track mode, including interleaved messages.
Total packets transmitted since the last reset. Rolls over at 65,535
Total times the transmitter attempted to lock the PLL so it could transmit and the
Any number here other than zero is a serious indication of a problem.
(It's possible the PLL might not lock in extreme high or low temperature conditions, but
generally speaking, anything other than zero here is probably bad.)
DESCRIPTION
Always a value of 0xAA
0x86 = Set Accelerometer On Off
0x00 = Off
0x01 = On
0x5
DESCRIPTION
Always a value of 0xAA
0x0C
PLL would not lock
0x06
44