Page 1
9100-0425-01 SmartOne Solar User Manual Confidential and Proprietary Information...
Page 2
300 Holiday Square Blvd. Covington, LA 70433 This guide is based on the production version of the Globalstar SmartOne Solar™. Software changes may have occurred after this printing. Globalstar reserves the right to make changes in technical and product specifications without prior notice.
Page 3
Fixed document number 1.0.4 1/5/2018 M. Pergola Updated Regulatory language Document Approval History Title Name Date Sales Sales (Simplex) Product Engineering Marketing Software and App Project Management Quality Related Documents Title Name Date SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
1. SmartOne Basics Overview The Globalstar SmartOne series of products are designed to track the positions of trailers, cargo containers, heavy construction equipment, generators, boats/barges and any other mobile assets. NOTE: Throughout the rest of this manual, the term SmartOne will refer to the SmartOne Solar™...
12:00 noon and 12:00 midnight. Reduced Messaging Reduced Messaging Mode reduces the cost associated with transmitting messages over Globalstar’s satellite network by sending messages at a minimal message interval when the asset is in a defined area and transmits at a higher message interval when the asset is changing locations.
SmartOne by using these two commands. The SmartOne connects to smart sensors via the SmartOne Serial Cable. The SmartOne Serial Cable is sold as an accessory. SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
9100-0425-01 Bluetooth Interface The SmartOne uses its built-in Bluetooth interface to advertise itself and for programming configuration settings. SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
For a Location Message, the SmartOne will wake up at a scheduled interval or time of day and begin to acquire a GPS fix. Once it receives its GPS fix, the SmartOne will transmit its location to the Globalstar Satellite Network.
Geostationary satellites also orbit at a much higher altitude and move along the equator. Messages are transmitted from the SmartOne via the Globalstar Satellite Network using an uplink-only connection (one-way data transmission) and received by a Globalstar Ground Station. The messages are then sent via an HTTP or FTP server to the internet and received by the VAR or end customer’s back...
The SmartOne unit can also be mounted on a flat vertical surface but this may reduce the communication reliability, decrease the maximum sustainable messaging rate, and may reduce the GPS location accuracy. SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
Peel the other side of the adhesive gasket and place the SmartOne onto the asset. Apply at 80lb (350N) of force to the unit for a minimum of three seconds to achieve full bonding strength. SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
The optional metal mounting bracket is used to firmly secure the device to the asset. It has four screws that attach the SmartOne Solar device to the asset. This allows the SmartOne Solar to be mounted such that the antennas have direct view of the sky with mounting flexibility. The SmartOne Solar attaches to the metal mounting bracket using four Phillips-head screws.
9100-0425-01 3. Messages The SmartOne produces on-air messages conforming to the Globalstar specified format. See Appendix G through J for detailed examples of various message decoding. The data being communicated to the end user is contained entirely in the 72 bit (9 byte) field.
At Rest rate or In Motion rate. Whether the device is At Rest or In Motion can be determined by the Motion bit (Byte 8, bit 6). SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
GPS location information. The input and status bits data of the standard message are replaced with user data from the configuration port. The Truncated message will follow the following on-air format: SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
They are presented to the user by the Globalstar back office as complete messages of a length longer than 9 bytes. The SmartOne supports user-defined messages (Class 1 and 2) of up to 54 bytes.
Page 20
Byte 1 = User data byte 1 Byte 2 = User data byte 2 Byte 3 = User data byte 3 …… User Data Variable …… …… Byte 47 = User data byte 47 SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
User Data Variable Byte 5 = User data byte 5 Byte 6 = User data byte 6 Byte 7 = User data byte 7 Byte 8 = User data byte 8 SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
From the user application point of view, this eliminates the 9 byte limitation allowing the user to compose longer messages transparently. They are presented to the user by the Globalstar back office as complete messages of a length longer than 9 bytes. The SmartOne supports user-defined messages (Class 1 and 2) of up to 54 bytes.
The SmartOne will send a Contact Service Provider message when an internal fault is detected. The SmartOne will send one such message upon the detection of an internal fault. It will then attempt to SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
SmartOne will send a standard message (Highest is listed first): • Rate specified by Undesired Input State. • Rate specified for when the SmartOne is inside its Change of Location Area. SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
If, for example, the user interface commands the device to send a Truncated message, and then, before it has time to obtain a fix and send the message, the user commands a Raw message, the Raw message will be sent. SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
Data Data associated with the command or answer Least significant byte of the 16-bit CRC CRC Low CRC High Most significant byte of the 16-bit CRC SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
ESN (Electronic contain the unit ID as an 0x01 Serial Number). This is the ID None unsigned integer. The used by Globalstar to identify the MSByte is sent first. Only unit the 27 LSbits are non-zero See Truncated Message 0x26...
000100xx (with the “xx” representing the two bits that the SmartOne forces to “01”). The 22 and the 33 that the user sent are appended after the 6 bytes of latitude and longitude. SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
“2”, the remaining 6 bits make up the top 6 bits of the first byte sent in the serial command, in this example 000100xx (with the “xx” representing the two bits that the SmartOne forces to “10”). SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
The handshake line should be pulled low before sending each serial message. The recommended use of the handshake line is: 1) Pull handshake low. 2) Wait 2-3 milliseconds. 3) Send command 4) Receive response. 5) Raise handshake high. SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
The SmartOne accepts a serial connection at 3 volt levels (Max), at 9600 baud. The relevant pins are TX, RX, Handshake and ground. The SmartOne can connect with devices that contain an asynchronous UART at 3 volt levels. (High State: 2.7-3 Volts, Low State: 0 Volts. Please contact Globalstar Support for more information).
Accumulate Hours – The activity time accumulated in the Inputs of the device while the Input is in the user defined state. Activation – The activation of an ESN (electronic serial number) on the Globalstar satellite network. The process consists of programming a start and an end date for the use of the ESN and the payment of certain fees to Globalstar.
Page 33
Globalstar only counts repeated messages as one message if it is received three times or less. If the same message is received more than three times, Globalstar may count the message as more than one message for billing purposes Self Test –...
Page 34
Undesired State Message – The SmartOne sends this message at a user defined interval while any of its Inputs are in the undesired state selected by the user, either closed or opened. SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
9100-0425-01 Appendix B - Technical Support We suggest VARs reference our online content at our Globalstar VAR Support Website http://var.globalstar.com/ prior to contacting our VAR Support. The content located there should address most activation/provisioning inquiries and minor frequently asked questions concerning business account management functions.
FCC RF determinees pour un environnement non controle. Cet equipment devrait etre installe et actionne avec une distance minimum de 20 cm entre le radiature et votre corps. SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
Cet Appareil numerique de la classe (A) est conforme a la norme NMB-003 du Canada. CE Notices DECLARATION OF CONFORMITY FOR EUROPEAN CUSTOMERS Hereby, Globalstar declares that this SmartOne Solar is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. The declaration of conformity may be consulted at www.Globalstar.com/Regulatory.
Page 38
SmartOne Solar™ Max Power Out: 23.46 dBm EIRP The SmartOne Solar has been so constructed that the product complies with the requirement of Article 10(2) as it can be operated in at least one Member State as examined and the product is compliant with Article 10(10) as it has no restrictions on being put into service in all of the EU except Ireland.
A separate grounding wire connected to the provided location on the bracket may also be used. The bracket may be painted or powder-coated provided the maximum coating thickness is less than 0.2mm. SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...
Appendix K). If the supply voltage to the SmartOne Solar is not at the rated voltage, the unit may not operate correctly and damage to the unit may occur. Also, it will void the warranty if an invalid voltage is supplied via external input and the SmartOne Solar is damaged.
NOTES: a) While functional in the specified Operating Temperature Range, usage of Operating/Storage the SmartOne Solar™ above 60°C may cause RF signal degradation and Temperature Range decreased battery lifetime of the unit. The unit is certified Intrinsically Safe for hazardous environments over the temperature range -40°...
Page 46
(PN# 2030-0265-04) INSTRUCTIONS 1. This cable is designed to work with the SmartOne Solar product only. Do not use with any other SmartOne product. 2. This cable is designed to work with 3V logic only. Do not use with 5V logic devices.
Page 47
The rechargeable NiMH batteries should last up to 6 months with a clear view of the sky in the absence of sunlight under any of the following mutually exclusive conditions: 1) Two Location Messages/day 2) Two nine-byte raw messages/day 3) Two GPS fixes/day SmartOne Solar™ User Guide v1.0.3 Confidential & Proprietary Information...