YASKAWA SI-C3/V Technical Manual page 32

Hide thumbs Also See for SI-C3/V:
Table of Contents

Advertisement

Extended Command Code
(Monitor Code)
Fault contents 3
122H
(1015H)
Fault contents 4
123H
(1016H)
Fault contents 5
124H
(1017H)
YASKAWA ELECTRIC SIEP C730600 22C V1000 Option CC-Link Technical Manual
Fault Name
BIT
0
MEMOBUS communication fault (CE)
1
Option communications error (bUS)
2
Reserved
3
Reserved
4
Control fault (CF)
5
Reserved
6
Option unit external fault (EF0)
7
PID feedback loss (FbL)
8
Undertorque detection 1 (UL3)
9
Undertorque detection 2 (UL4)
A
High Slip Braking overload (oL7)
B
Reserved
C
Reserved
D
Reserved
E
Reserved
F
Hardware fault (including oFx)
0
Reserved
1
Reserved
2
Reserved
3
Reserved
4
Reserved
5
Output current imbalance (LF2)
6
Pullout detection (STo)
7
Reserved
8
Reserved
9
Reserved
A
Too many speed search restart (SEr)
B
Reserved
C
Reserved
D
Reserved
E
Reserved
F
Reserved
0
Excessive PID feedback (FbH)
1
External fault (input terminal S1) (EF1)
2
External fault (input terminal S2) (EF2)
3
Mechanical weakening detection 1 (oL5)
4
Mechanical weakening detection 2 (UL5)
5
Current offset fault (CoF)
6
Reserved
7
Reserved
8
DriveWorksEZ fault (dWFL)
9
Reserved
A
Reserved
B
Reserved
C
Reserved
D
Reserved
E
Reserved
F
Reserved
10 CC-Link Code Numbers
Fault Code (U2, U3)
0021H
0022H
0025H
0027H
0028H
0029H
002AH
002BH
0030H
0036H
0037H
003BH
0041H
0042H
0043H
0044H
0045H
0046H
0049H
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac drive-v1000 option cc-link

Table of Contents