  • Page 1 YASKAWA AC Drive-V1000 Option LCD Operator Installation Manual Type JVOP-180 To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this manual. MANUAL NO. TOBP C730600 29A...
  • Page 2 Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice.
  • Page 3: Table Of Contents

    9 SPECIFICATIONS ....... . . 37 YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 4: Preface And Safety

    The selection and application of Yaskawa products remain the responsibility of the equipment manufacturer or end user. Yaskawa accepts no responsibility for the way its products are incorporated into the final system design. Under no circumstances should any Yaskawa product be incorporated into any product or design as the exclusive or sole safety control.
  • Page 5 Terms Drive: Yaskawa AC Drive -V1000 Series. LCD Operator Option: JVOP-180 LCD Operator unit for the Yaskawa V1000 drive. Note: Indicates a supplement or precaution that does not cause drive damage. Indicates a drive feature or function that is only available in drive software ≥...
  • Page 6 Indicates a hazardous situation, which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury. NOTICE Indicates an equipment damage message. YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 7 • When ordering a new copy of the manual due to damage or loss, contact your Yaskawa representative or the nearest Yaskawa sales office and provide the manual number shown on the front cover.
  • Page 8: Product Overview

    The LCD Operator Option provides an enhanced drive user interface that can operate the Yaskawa drive at a short distance up to 3 meters. The LCD Operator Option can display information in eight languages, including English, Japanese, and Spanish.The LCD Operator...
  • Page 9 The LCD Operator Option can be used with the drive models in Table Table 2 Applicable Drive Models Drive Drive Software Version <1> ≥1012 CIMR-V ≥1012 CIMR-V ≥1012 CIMR-V <1> See “PRG” on the drive nameplate for software version number. YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 10: Receiving

    Refer to Installing the LCD Operator Option on page 21 more information regarding installation methods. To order a cable or an installation support, contact Yaskawa directly or your nearest Yaskawa distributor. YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 11 Installation Support Required Tools External/Face Mount – Phillips screwdriver, M3 Installation Set A Phillips screwdriver, M3, M4 Internal/Flush Mount Phillips screwdriver, M3 Installation Set B Box end or adjustable wrench, M4 YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 12: Lcd Operator Option Components

    A – LCD Display D – Installation Mounting Holes B – ALARM (ALM) LED E – Nameplate C – Keys F – Communication Cable Connector Figure 1 LCD Operator Option Components YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 13 • Moves the cursor to the right. RESET Key • Resets the drive to clear a fault situation. RUN Key Starts the drive and motor. R R U U N YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 14 Refer to LCD Operator LED Status Indicators on page 15 detail. Illuminated while the drive is under LCD Operator control when LO/RE Light (LOCAL) is selected to run the drive. YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 15 <1> For the difference between “Flashing” and “Flashing Quickly” of the RUN LED, refer to Figure 3, RUN LED Status. Figure 3 Flashing Flashing quickly Figure 3 RUN LED Status YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 16 4 LCD Operator Option Components Figure 4 Drive output frequency During stop STOP STOP STOP 6 Hz 0 Hz Frequency setting RUN LED Flashing Figure 4 RUN LED and Drive Operation YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 17 Displayed when in Drive Mode. Mode Display Area Displayed when in Programming Mode. Ready Indicates the drive is ready to run. Data Display – Displays specific data and operation data. YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 18 (F1) HOME Pressing returns to the top menu (Frequency Reference). Pressing returns to the previous display. Indicates forward motor operation. FWD/REV Indicates reverse motor operation. YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 19 When the drive detects an alarm or error. • When an alarm occurs. Flashing • When oPE is detected. • When a fault or error occurs during Auto-Tuning. Normal operation (no fault or alarm). YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 20: Installation Procedure

    Failure to comply may prevent proper operation and possibly damage equipment. Do not exceed communication cable bend radius specifications. Failure to comply may result in broken wires or loose connections. YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 21 44 (1.73) (0.31) minimum 50 (1.97) Unit : mm (in) Figure 6 Dimensions <1> Use only Yaskawa cables or cables recommended by Yaskawa. Refer to Item Names and Part Numbers (Sold Separately) on page ◆ Installing the LCD Operator Option There are two different installation methods for the LCD Operator Option depending on the application.
  • Page 22 × 2 Enclosure panel Unit : mm (in) Figure 7 External/Face-mount Installation Figure 8 22 (0.87) 22(0.87) (0.55) Unit : mm (in) Figure 8 Panel Cut-out Dimensions (External/Face-mount Installation) YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 23 Note: For environments with a significant amount of dust or other airborne debris, use a gasket between the enclosure panel and the LCD Operator Option. Figure 10 45 (1.77) +0.5 +0.02 2.32 Unit : mm (in) Figure 10 Panel Cut-out Dimensions (Internal/Flush-mount Installation) YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 24 Built-in LED Display Behavior with a Connected LCD Operator Option. Note: Use only Yaskawa recommended cables. Using a cable not specified may cause the LCD Operator or drive to malfunction. Note: The STOP key on the drives built-in LED operator is the only functional key on the built-in LED operator when the LCD Operator Option is connected to the drive and parameter b1-02 is set to 0 (LCD Operator Option).
  • Page 25: Basic Operation

    <5> The Frequency Reference appears after the initial display. <6> The information that appears on the display will vary depending on the drive. Figure 12 LCD Operator Option Menu Structure YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 26 → -MONITR- FREF (d1-01) 3. Press until the frequency U1-01= 006.00Hz 0.00 60.00 reference changes to 006.00 Hz. 0.00Hz ← → 4. Press to set the output frequency. Entry Accepted YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 27 Monitor display. U1-02= 0.00Hz LSEQ LREF U1-03= 0.00A FWD/REV -MONITR- Last Fault U2- 02= oPr 4. Press to view the drive monitors. U2-03= 0.00Hz LSEQ U2-04= 0.00Hz LREF FWD/REV YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 28 → -PRMSET- Select Language 4. Press to select A1-00 A1-00= English and press “1” ← → -PRMSET- ゲンゴ Language 5. Press to enter setting 1. A1-00= ニホンゴ Japanese ← → YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 29 3. Press to show the Initialization display. A1-00= Select Language ← → -PRMSET- Accel Time 1 4. Press to select parameter C1-01= 0010.0Sec (0.0~6000.0) C1-01 and press “10.0 sec” ← → YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 30 Note: The LCD Operator Option can perform the Read function an estimated 100,000 times. Copy Copies the parameter settings from the LCD Operator Option to another Yaskawa drive. Verify Verifies that parameter settings in the drive match the parameter settings saved to the LCD Operator Option.
  • Page 31 4. Press to select o3-01 and press o3-01= COPY SELECT ← → -PRMSET- Copy Funtion Sel 5. Press to enter 1 (INV --> OP READ). o3-01= INV→OP READ ← → YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 32 6 Basic Operation 6. Press and the LCD Operator Option will read the parameter READ settings from the drive. INV→OP READING 7. Automatically return to the Copy Function Selection display. READ COMPLETE YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 33: Related Parameters

    0: Operator - RUN and STOP keys on the LCD Operator Option b1-16 Command 1: Digital input terminals S1 to S7 Source 2 2: MEMOBUS/Modbus serial communications 3: Option PCB YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 34 (o2-04), software number (U1-14), and control method (A1-02) must match or an error will occur. Enables or disables reading of drive parameter settings. Copy o3-02 0: Disabled - Read not allowed Allowable 1: Enabled - Read allowed YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 35: Lcd Operator Option Fault Diagnostics

    When an LCD Operator Option fault occurs, ensure that the communication cable is properly connected to the LCD Operator Option and it is not loose. Contact your nearest Yaskawa representative or sales department if the cable appears to be connect properly but still no message appears to indicate the error.
  • Page 36 • Turn off the drive input power and disconnect the LCD Operator Option. Reconnect the LCD Operator Option and reapply drive input power. <1> Display will vary depending on operation status. YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...
  • Page 37: Specifications

    Estimated 100,000 times Limitation <1> The LCD display may respond more slowly if the ambient temperature falls below freezing. Higher temperatures can also shorten the performance life of the LCD display. YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual...