Securing the machine against restart

24
WARNING!
Risk of fatal injury if the plant is switched back on uncon-
trolledly or without authorization!
Switching the Börger machine on without authorization or uncon-
trolledly can cause serious injuries.
— Before switching back on, make sure that all safety devices
are fitted and fully functional and that staff are not at any risk.
— Always adhere to the sequence to secure the plant to prevent
it from being switched back on according to
"Securing the machine against restart" on page 24.
1.
Shut off the media supply by closing the respective shut-off
valves.
2.
Shut off the energy supply.
3.
Inform the person responsible that work is being carried out
in the danger area.
4.
Attach a sign to the control cabinet to indicate that work is
being carried out in the danger area and that switching on is
prohibited. The sign must include the following information:
— Switched off on:
— Switched off at:
— Switched off by:
— Important notice: Do not switch on!
— Important notice: Do not switch on before ensuring that
personnel are at no risk.