9.8.1
Börger gear units
188
Oil quality
Only oils containing active substances for improving corrosion pro-
tection and aging resistance and reducing wear in gear units are
permitted for use in Börger gear units.
Additionally, the gear oils must also meet the following quality
requirements:
— Suitable for lip seal material and gear casing material
— Compatible with residual oil originally used by the manufacturer
— Sufficient viscosity for the relevant temperature range
NOTICE!
Risk of material damage and loss of warranty when using
low-quality lubricants!
The oil classification and viscosity must be adhered to according
to the factory-supplied lubricant specified in the data sheet.
The lubricants used must meet the quality standards as detailed
above. Otherwise, the warranty supplied by Börger GmbH is void.
Deviations are only permitted following consultation with Börger
GmbH.
If the actual operating conditions on or after commissioning deviate
from those specified in the order, then a change of lubricant must
be considered. Any such actions must be approved by Börger
GmbH.
Lubricants suitable for use in Börger gear units are listed in
Ä Chapter 9.8.4 "Oil types" on page 192. However, the lubricant
manufacturers are solely liable for the suitability and quality of their
products.
According to the manufacturer's specifications, the listed lubricants
are available globally in compliance with the necessary quality.
Oil change
www.boerger.de / www.boerger.com
BA-Classic FL_en-US, 03.05.2018
Appendix