Querying The Prosthesis Status; Query Status Through Cockpit App; Status Display In The Cockpit App; Mute Mode (Silent Mode) - Otto Bock Genium 3B1 Instructions For Use Manual

Bionic prosthetic system
Hide thumbs Also See for Genium 3B1:
Table of Contents

Advertisement

Available languages

Available languages

→ Bluetooth is switched on for approx. 2 minutes. During this time, the app must be started
in order to establish a connection to the component.
2) Follow the on-screen instructions.
→ If Bluetooth is switched on, the

8.4 Querying the prosthesis status

8.4.1 Query status through cockpit app

1) When the component is connected, tap the  symbol in the main menu.
2) In the navigation menu, tap the entry "Status".

8.4.2 Status display in the cockpit app

Menu option
Trip
Step
Service
Batt.
Stb/Act: 58/29

8.5 Mute mode (silent mode)

Activating mute mode (silent mode) turns off the audible feedback signals and the vibration sig­
nals. However, warnings in case of component errors are still generated (see Page 100).
Mute mode can be activated/deactivated using the Cockpit app.
INFORMATION
Connecting the battery charger automatically deactivates mute mode again.

8.5.1 Turning mute mode on/off using the Cockpit app

1) When the component is connected, tap the  symbol in the main menu.
→ The navigation menu opens.
2) In the navigation menu, tap the entry "Functions".
3) Tap the entry "Mute mode".
4) Follow the on-screen instructions.

8.6 OPG function (Optimised Physiological Gait)

INFORMATION
The O&P professional can turn the "PreFlex" function on or off using the adjustment software.
All other parameters of the OPG function are always active and cannot be influenced.
The OPG function minimises the prosthesis wearer's prosthetic deviations from a harmonious gait
pattern and promotes more biomechanically correct walking. This function enables the following
features:
88
 symbol appears on the screen.
Description
Daily step counter (steps with
the prosthesis side)
Total step counter (steps with
the prosthesis side)
Display of the next mainten­
ance date
Current prosthesis charge
level, as a percentage
Estimated remaining operating
time of prosthesis in hours.
Rest mode (Stb) e.g.
58 hours, active use (Act) e.g.
29 hours
Possible actions
Reset the counter by tapping
the "Reset" button.
For informational purposes
only
For informational purposes
only
For informational purposes
only
For informational purposes
only