ETC User Guide
QuickTouch Preset
Advanced Configuration
Open the Advanced dialog for any channel to access the following tabs and their respective
functions.
Trims: Allows you to set trims for the motor
•
Load: Provides load information for the motor
•
Speed: Provides speed information for the motor
•
Status: Provides system status and history
•
Statistic: Provides statistical information
•
Diagnostic: Provides diagnostic information
•
Load Profiling
It is highly recommended that you enable load profiling for your motors. This feature allows you to
record a normal profile of what the load should be at any point in the full range of travel, in both
directions. Load profiling then monitors the load during movement and stops movement when
unexpected load conditions occur.
To record these load profiles and subsequently enable load profiling:
1. Select the Load tab and press the Learn button.
For standard loads (i.e. scenery or non-electric loads), press the Save button.
•
For loads that change during travel, press the Record button.
•
Record the up and down profiles for the load
-
Save the profiles when you are satisfied
-
Close the Learn Load dialog
-
2. From the Load tab, you can now select the Enable Profiling button (outlined in
selected).
3. You can also change the sensitivity setting per motor, with Maximum having the lowest
tolerance for deviance from the load profile and Low having the greatest tolerance.
Speed Configuration
Select the Speed tab and press the Max Speed field. In the dialog that appears, enter the
maximum speed at which you would like the motor to run. Press the Min Ramp Time field and in
the dialog that appears, enter the minimum ramp time.
QuickTouch Preset
Page 7 of 15