SPECIFIC GRAVITY
State of
Conventional
charge*
lead-acid
100%
1.265
Charged
1.210
75% Charged
1.160
50% Charged
1.120
25% Charged
less than 1.100
0% Charged
* At 80_F
NOTE: Subtract .01 from the specific gravity reading at 40_ F.
LOAD TEST
CAUTION:
To prevent shock or component
damage, remove spark plug high tension leads
and connect securely to engine ground before
proceeding.
NOTE: This test can only be performed on machines
with electric starters. This test cannot be performed
with an engine or starting system that is not working
properly.
A battery may indicate a full charge condition in the OCV
test and the specific gravity test, but still may not have
the storage capacity necessary to properly function in
the electrical system. For this reason, a battery capacity
or load test should be conducted whenever poor battery
performance is encountered. To perform this test, hook
a multitester to the battery in the same manner as was
done in the OCV test. The reading should be 12.6 volts
or greater. Engage the starter and observe the battery
voltage while cranking the engine. Continue the test for
15 seconds. During cranking the observed voltage
should not drop below 9.5 volts. If the beginning voltage
is 12.6 volts or higher and the cranking voltage drops
below 9.5 volts during the test, replace the battery.
OFF SEASON STORAGE
To prevent battery damage during extended periods
of non-use, the following basic battery maintenance
items must be performed:
GRemove the battery from the machine
and wash the case and battery tray
with a mild solution of baking soda
and water. Rinse with lots of fresh
water after cleaning. NOTE: Do not
get any of the baking soda into the
battery or the acid will be neutralized.
GUsing a wire brush or knife, remove any
corrosion from the cables and
terminals.
GMake sure that the electrolyte is at the
proper level. Add distilled water if
necessary.
YuMicront
Type
1.275
1.225
1.175
1.135
NOTE: Stored batteries lose their charge at the rate
less than 1.115
of 1% per day. Recharge to full capacity every 30 to
60 days during a non-use period. If the battery is
stored during the winter months, electrolyte will freeze
at higher temperatures as the battery discharges.
The chart below indicates freezing points by specific
gravity.
CHARGING PROCEDURE
1. Remove the battery from the ATV to prevent
2. Charge the battery with a charging output no
3. Install battery in vehicle with positive terminal
4. Connect battery cables.
To avoid the possibility of explosion, connect positive
(red) cable first and negative (black) cable last.
5. After connecting the battery cables, install the
GCharge at a rate no greater than 1/10 of
the battery's amp/hr capacity until
the electrolyte's specific gravity
reaches 1.270 or greater.
GStore the battery either in the machine
with the cables disconnected, or
store in a cool place.
Electrolyte Freezing Points
Specific Gravity
of Electrolyte
1.265
1.225
1.200
1.150
1.100
1.050
damage from leaking or spilled acid during
charging.
larger than 1/10 of the battery's amp/hr rating.
Charge as needed to raise the specific gravity to
1.270 or greater.
toward the front. Coat threads of battery bolt with
a corrosion resistant dielectric grease.
Dielectric Grease
(PN 2871329)
WARNING
cover on the battery and attach the hold down
strap.
ELECTRICAL
Freezing
Point
-75° F
-35° F
-17° F
+5° F
+18° F
+27° F
10.13