Appendix B: Default Programming - Honeywell FIre-LITe ALArms MS-9600LS Manual

Addressable fire alarm control panel
Hide thumbs Also See for FIre-LITe ALArms MS-9600LS:
Table of Contents

Advertisement

Appendix B: Default Programming

The following table provides a list of the programming options and their factory default settings.
Program Option
Master Password
Maintenance Password
Detector Programming
Detector Type
Detector Verification
Detector Walktest
Detector PAS
Detector Presignal
Detector Zone Assign.
Detector Adj/Noun
Module Programming
Module Type
Module Walktest
(not used)
Module Presignal
Module Zone Assign.
Module Adj/Noun
Zone 0 Enable
Zone 1 Enable
Zone 2 Enable
Zone 3 Enable
.........................through..........
Zone 99 Enable
Special Zones 97, 98 & 99
Zones 0 - 99 Type
Loop 1 & 2 Style
Loop 1 & 2 Protocol
Trouble Reminder
Banner
Time Format
Hours Setting
Minutes Setting
Second Settings
AM-PM Setting
Month Setting
Day Setting
Year Setting
PK-Plus Secret Code
Trouble Call Limit
Daylight Savings
Month Start Daylight Savings
Week Start Daylight Savings
Month End Daylight Savings
Week End Daylight
Verification
Ring Count
PAS Timer
Presignal Timer
Waterflow Retard Timer
186
Factory Default
Program Option
00000
NAC Enable
11111
NAC Silenceable
Not Installed
NAC Type
Smoke-Photo
NAC Sync Type
Off
NAC Autosilence
Yes
NAC Coding
No
NAC Zones
No
NAC Silence Inhibit
000 only
Relay 1
none
Relay 2
Not Installed
Relay 3
Monitor
On Board DACT
Yes
Annunciator Terminal Mode
Annunciator ACS Mode
No
UDACT
000 only
ACS Installed
none
Printer-PC
Enabled
Printer Baud
Enabled
Canadian Option
Enabled
Waterflow Silenceable
Enabled
ANN-BUS Enabled
.....................
Central Station Reporting
Enabled
AC Loss Delay
Disabled
DACT Backup Reporting
Monitor
DACT Report Style
Style 4
ANN Enabled
LiteSpeed
ANN-BUS Modules Addr. 1 - 8
Off
ANN-S/PG Port
ANN-S/PG Baud
12 Hr
ANN-S/PG Data Bits
12
ANN-S/PG Parity
00
ANN-S/PG Stop Bits
00
ANN-S/PG Offline Timer
AM
ANN-S/PG Printer Supervision
01
ANN-80 Piezo Enabled
01
ANN-80 Lock Enabled
00
ANN-80 Acknowledge Button Enabled
00000000
ANN-80 Silence Button Enabled
0
ANN-80 Reset Button Enabled
Yes
ANN-80 Drill Button Enabled
March
ANN-I/O Point/Zone
2nd Week
ANN-I/O Range
November
ANN-I/O Active LEDs Only
1st Week
ANN-RLY Relay 1
No
................through.......................
0
ANN-RLY Relay 10
0
ANN-LED Point/Zone
0
ANN-LED Alarms/ATS (Alarm, Trbl, Supv)
0
ANN-LED Range
MS-9600LS Series Manual — P/N 52646:B2 2/12/2010
Factory Default
Enabled
Yes
Bell
System Sensor
0
Steady
Zone 000 only
0
Alarm
Trouble
Supervisory
No
No
No
No
No
No
9600
Off
No
No
Disabled
2 Hours
First Available
By Point
No
None
Parallel
9600
7
Even
1
60
No
Yes
Yes
Yes
Yes
Yes
Yes
Zone
00-29
Zone 1
............
Zone 10
Zone
ATS
0 - 9