Regular Safety Checks - Assa Abloy SL500 Owner's Manual

Sliding door operator
Hide thumbs Also See for SL500:
Table of Contents

Advertisement

Regular safety checks

To help you fulfil the national/international requirements and to avoid malfunction and risk
for injuries, we have provided the following checklist.
Do not use if repair or adjustment is necessary.
Disconnect supply when cleaning or other maintenance is to be carried out.
Activate your operator and visually check, fastening of
program selector(s)
door and glass (stability)
Also inspect your operator and check visually for
condition of door seals and weather stripping
condition of glazing vinyl
finger protection
proper operation; opens smoothly, closes slowly and smoothly
any ventilation being obstructed
Set the program selector to OFF and check that the operator and electromechanical
lock (if fitted) work together. Also confirm the door locks.
Activate the knowing act devices, if any, and walk towards the door. Check that the
door has opened appropriately while you pass the entrance/exit.
Then proceed with the automatic activation units in the same way, see page 9.
Check the safety sensors if any, see page 10. If you are unsure of which type of
sensor you have, please contact your ASSA ABLOY representative.
Escape doors
If the operator is equipped with break-out system, set the program selector to
AUTO mode. Push the door manually in the escape direction to ensure that nothing
prevents the door from being opened. Also ensure that the escape route is free for
use. After the test, restore the door(s) to their normal mode of operation.
= Take appropriate measures.
= Contact your ASSA ABLOY representative. For contact information, see last page.
12