I/O functions:
-
Fire alarm connection
Used to emergency open or fire close the door with mains power on.
-
External error indication
Obtained if a lamp or a buzzer is connected.
-
Open / Close function
A one button impulse, will alternate between Open and Close. The door will stand open until
next impulse or can after an adjustable time delay automatically start to close even if a new
impulse is not received.
-
Nurse function
A pedestrian partial opening in operation mode selections Exit, Auto and Auto partial. The
Nurse impulse hold open time is adjustable.
-
Night mode
Remotely put door into exit only via an automated system. Requires a NO contact.
I/0 unit (IOU) P/N: 1007779