Deep discharge protector
"Lo" appears in the display, the "Battery capacity" indicator flashes
Cause:
Remedy:
Danger due to prolonged storage of the battery in a discharged state.
This can damage the battery.
Service mes-
When E and a 2 digit error number appear in the display (e.g. E02) and the "Error"
sages
indicator lights up, this is an internal power source service code.
Example:
It is also possible that several error numbers are present. These appear when
turning the adjusting dial.
Make a note of the error numbers shown in the display, and of the serial number
and configuration of the power source, and contact our after-sales service team
with a detailed description of the error.
E02 / E03 / E05 / E06
Cause:
Remedy:
E07 / E72
Cause:
Remedy:
E09 / E10
Cause:
Remedy:
E11
Cause:
Remedy:
E12 / E13 /E14
Cause:
Remedy:
62
+
Battery discharged, deep discharge protection has been activated
Charge the battery now
Battery operation is possible again above 25% capacity
CAUTION!
If the deep discharge protector is triggered, charge the power source
promptly!
Internal temperature sensor fault on ACCUPLT / ACCUPLT-TIG PC
board
Contact after-sales service
Internal supply voltage 15 V outside the valid range
Contact After-Sales Service
Load too high on power source current sockets
Use power source correctly (welding)
No communication with the control panel
Contact after-sales service
Internal error on ACCUPLT / ACCUPLT-TIG PC board
Contact after-sales service