Functional description and configuration using Web Based Management
9.7 The "System" menu
Note
Note the following points about restarting a SCALANCE X-200RNA:
• You can only restart the SCALANCE X-200RNA with administrator privileges.
• A SCALANCE X-200RNA should only be restarted with the buttons of this menu and not by a
power cycle on the device.
• The browser must not be set so that it reloads the page from the server each time the page
is accessed. The updating of the dynamic content of the page is ensured by other
mechanisms. In the Internet Explorer, you can make the appropriate setting in the "Options
> Internet Options > General" menu in the section "Temporary Internet Files" with the
"Settings" button.
• Below the text "Check for newer versions of stored pages", the "Automatically" check box
must be selected.
Restart System
Click the "Restart System" button to restart the SCALANCE X-200RNA. You are prompted to
confirm the restart in a separate dialog box. During a restart, the SCALANCE X-200RNA is
reinitialized, the internal firmware is reloaded, and the device runs a self-test. The learned
entries in the address table are deleted. You can leave the browser window open while the
SCALANCE X-200RNA restarts.
Restore Factory Defaults and Restart
Click the "Restore Factory Defaults and Restart" button to restore the factory default
configuration settings. The protected defaults are also reset. An automatic restart is triggered.
Note
By resetting all the defaults, the IP address is also lost. A SCALANCE X‑200RNA can then be
accessed using SINEC PNI.
9.7.4
System Save & Load
System Save & Load via HTTP
The WBM allows you to store configuration information in an external file on your client PC or to
load such data from an external file from the PC to the SCALANCE X-200RNA. You can also
download both new firmware as well as a new FPGA configuration from suitable files on your
client PC.
Note
Following a firmware update, delete the cache of the Web browser.