11.2

PRP-compatible devices

PRP-compatible devices
For a device to be used in PRP networks, it must be able to process a frame length of at least 1528
bytes (Jumbo Frames). This value is the maximum frame length including VLAN tag of
1522 bytes plus the length of the PRP trailer of 6 bytes.
The SCALANCE X devices meet these requirements with a few exceptions. You will find the exact
"Maximum frame size" value in the technical specifications of the respective operating
instructions.
The devices listed below are suitable for use in PRP networks as of a specific version.
Product
SCALANCE X005, unmanaged IE switch
SCALANCE X005-TS, unmanaged IE switch, printed-circuit board
painted, -40 °C ... +75 °C
SCALANCE X204-2, managed IE switch
SCALANCE X204-2TS, managed IE switch
SCALANCE X204-2LD, managed IE switch
SCALANCE X206-1, managed IE switch
SCALANCE X206-1LD, managed IE switch
SCALANCE X208, managed IE switch
SCALANCE X208PRO, managed IE switch
SCALANCE X212, managed IE switch
SCALANCE X212-LD, managed IE switch
SCALANCE X216, managed IE switch
SCALANCE X224, managed IE switch
SCALANCE XF204, managed IE switch
SCALANCE XF204-2, managed IE switch
SCALANCE XF206-1, managed IE switch
SCALANCE XF208, managed IE switch
RUGGEDCOM RS950G, managed PRP Redundancy Box
SCALANCE X304-2FE, managed IE switch
SCALANCE X306-1LD FE, managed IE switch
SCALANCE X307-3, managed IE switch
SCALANCE X307-3LD, managed IE switch
SCALANCE X308-2, managed IE switch
SCALANCE X308-2LD, managed IE switch
SCALANCE X308-2LH, managed IE switch
SCALANCE X308-2LH+, managed IE switch
SCALANCE X310, managed IE switch
SCALANCE X310-FE, managed IE switch
SCALANCE X-200RNA
Operating Instructions, 04/2022, C79000-G8976-C342-07
Accessories and compatible devices
Article number
6GK5 005-0BA00-1AA3
6GK5 005-0BA00-1CA3
6GK5 204-2BB10-2AA3
6GK5 204-2BB10-2CA2
6GK5 204-2BC10-2AA3
6GK5 206-1BB10-2AA3
6GK5 206-1BC10-2AA3
6GK5 208-0BA10-2AA3
6GK5 208-0HA10-2AA6
6GK5 212-2BB00-2AA3
6GK5 212-2BC00-2AA3
6GK5 216-0BA00-2AA3
6GK5 224-0BA00-2AA3
6GK5 204-0BA00-2AF2
6GK5 204-2BC00-2AF2
6GK5 206-1BC00-2AF2
6GK5 208-0BA00-2AF2
6GK6 095-0GS1-... ("..." means, de‐
pending on combination)
6GK6 095-0GS2-...("..." means, de‐
pending on combination)
6GK5 304-2BD00-2AA3
6GK5 306-1BF00-2AA3
6GK5 307-3BL00-2AA3
6GK5 307-3BM00-2AA3
6GK5 308-2FL00-2AA3
6GK5 308-2FM00-2AA3
6GK5 308-2FN00-2AA3
6GK5 308-2FP00-2AA3
6GK5 310-0FA00-2AA3
6GK5 310-0BA00-2AA3
11.2 PRP-compatible devices
As of version *
HS 7
HS 7
V4.4
V4.4
V4.4
V4.4
V4.4
V4.4
V4.5
V4.4
V4.4
V4.4
V4.4
V4.4
V4.4
V4.4
V4.4
V3.11.1
V3.7.0
V3.7.0
V3.7.0
V3.7.0
V3.7.0
V3.7.0
V3.7.0
V3.7.0
V3.7.0
V3.7.0