Device description
5.1 Functions
Properties
Testing to IEC 61850-3
Testing to IEEE 1613
Note
PROFINET controllers can communicate with PROFINET devices via the HSR and PRP network
(PROFINET IO and RT). In this case all PROFINET devices (controllers and devices) must either be
capable of HSR or PRP themselves or must be connected to the HSR ring or to the PRP network
via a RedBox.
Within a PRP network (A or B), PROFINET controllers and devices can also communicate with
each other as SANs (PROFINET IO, RT and IRT). A direct PROFINET communication relationship
between DANPs and SANs or DANHs and SANs is not supported.
Table 5-1
Fast Ethernet 100 Mbps
TP (RJ‑45)
Fiber
multimode
(duplex LC)
Fiber
single mode
(duplex LC)
Fiber
single mode
(duplex LC)
Standard Ethernet ports / PRP
ports
HSR ports
Note
TP connectors of SCALANCE X204RNA EEC
The SCALANCE X204RNA EEC has 2 RJ-45 ports to which you can connect two standard Ethernet
or PRP end devices/network structures without HSR capability.
The SCALANCE X204RNA EEC also has 2 RJ-45 ports and 2 SFP slots. These connection options
communicate with each other; in other words only one connector is ever active. If an SFP module
is inserted, the corresponding RJ-45 jack is disabled.
With these connector options, you can connect the device to an HSR ring.
32
Possible connections
SCALANCE X204RNA
4
-
-
-
P1/A, P2/B
HSR 1, HSR 2
SCALANCE X204RNA
-
-
Operating Instructions, 04/2022, C79000-G8976-C342-07
SCALANCE X204RNA EEC
SCALANCE X204RNA EEC
2+2
2 x SFP modules SFP991-1
multimode glass up to 3 km
6GK5991-1AD00-8AA0
2 x SFP modules SFP991-1LD
monomode glass up to 26 km
6GK5991-1AF00-8AA0
2 x SFP modules SFP991-1LH+
monomode glass up to 70 km
6GK5991-1AE00-8AA0
P1/A, P2/B
HSR 1, HSR 2
SCALANCE X-200RNA