Midtronics DSS-5000PKIT User Manual page 11

Battery diagnostic service system
Table of Contents

Advertisement

DSS-5000
Test Results - Alternator
Decision
The output from the alternator is normal.
CHARGING
NORMAL
No output detected. Check belts to ensure
alternator is rotating when engine is running.
Check all alternator connections including
NO OUTPUT
to the battery. Clean or replace if
necessary and retest.
If the belts and connections are in good
working condition, replace alternator or
external voltage regulator.
Alternator not providing enough current to
power electrical loads and charge the battery.
Check belts to ensure the alternator is
LOW
rotating with the engine running.
OUTPUT
Check alternator connections to and from
the battery. If loose or heavily corroded,
clean or replace the cable and retest.
Alternator voltage to the battery exceeds
normal limits of a functioning regulator.
Check for loose and normal ground
HIGH
connections. If no connection problems
OUTPUT
are found, replace the regulator.
The normal high limit of a typical automotive
regulator is 14.5 volts +/–0.5. Refer to the
manufacturer specifications for the correct limit,
which may vary by vehicle type.
Test Results - Diode
Decision
One or more diodes in the alternator are not
functioning or there is stator damage, which is
shown by an excessive amount of AC ripple
EXCESSIVE
current supplied to the battery.
RIPPLE
Make sure the alternator mounting is
sturdy and that the belts are in good
shape and functioning properly. If the
mounting and belts are good, replace the
alternator.
OPEN PHASE
Replace the alternator.
OPEN DIODE
SHORTED
DIODE
Action
Action
13
Chapter 2: In Vehicle Test

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DSS-5000PKIT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Dss-5000

Table of Contents