Midtronics xMB-9640 User Manual

Midtronics xMB-9640 User Manual

Module balancer
Hide thumbs Also See for xMB-9640:

Advertisement

December 2020
167-000966EN-A
xMB-9640
Module Balancer
Users Guide

Advertisement

Table of Contents
loading

Summary of Contents for Midtronics xMB-9640

  • Page 1 December 2020 167-000966EN-A xMB-9640 Module Balancer Users Guide...
  • Page 2 Failure to follow these instructions may result in personal injury or death The xMB-9640 has not been designed for exposure to rain or snow. Operate the xMB-9640 only indoors in a clean environment. Failure to follow these instructions may resulit in equipment damage.
  • Page 3: Table Of Contents

    Language Settings 1. Maintenance System Language 2. Personal Precautions Test Result Language 3. Grounding & Power Cord Connections 6 Email Language 4. xMB-9640 Location Print Language Product Specifications Display Settings Brightness 1 – Introduction & Overview Version Information Factory Reset...
  • Page 4: General Safety Guidelines

    (457mm) above grade. Failure to follow this instruction may result in personal injury or death. • Periodic inspection and care are highly recommended, especially if the xMB-9640 is operating in a harsh environment. • Inspect for signs of overheating, rust, paint deterioration and general condition of the unit. If corrective measures should be taken, contact Midtronics.
  • Page 5 1.8 Do not overcharge the battery (See Section 3). 1.9 Charge the battery in a dry, well-ventilated area. 1.10 Never place articles on or around the xMB-9640, or locate the xMB-9640 in a way that will re- strict the flow of cooling air through the cabinet.
  • Page 6: Personal Precautions

    A battery can produce a short circuit current high enough to weld such items causing a severe burns. 2.6 The xMB-9640 is not intended to supply power to a low-voltage electrical system other than applications using rechargeable batteries.
  • Page 7: Xmb-9640 Location

    General Safety Guidelines xMB-9640 3.2 This xMB-9640 is for use on a nominal 120 volts or 240 volts circuit. The 120V grounding plug looks like the plug illustrated in Figure A. GROUNDED OUTLET GROUNDED OUTLET GROUNDING PIN GROUNDING PIN 3.3 Use of an extension cord could result in a risk of fire and electric shock.
  • Page 8: Product Specifications

    , 20A Humidity • 15% to 85% R.H., non-condensing • Dimensions (without handle or base) • 44 CM (L) X 43,5 CM (W) X 23 CM (H) • Weight: 17,84 KG (39 LBS) Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527...
  • Page 9: Introduction & Overview

    • Battery electrolyte can be hazardous. Refer to Material Safety Data Sheet for precautions and safety procedure for the type of battery being serviced • Keep hair, hands, and clothing as well as the xMB-9640 cords and cables away from moving engine parts.
  • Page 10 A list of detected wireless networks is displayed with  next to the selected network. > • Tap to access the network Security and IP Settings. Security None WPA/WPA2 PSK IP Address DHCP Static Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527...
  • Page 11 For Ford Dealers, enter dealership P&A Code. If not a Ford dealer, the BMIS Login screen is displayed. If you have a Midtronics BMIS account, enter your Username and Password. Tap X to skip. Contact Midtronics for inquiries regarding Midtronics BMIS accounts.
  • Page 12: Main Menu Icons

    Settings Module BMIS, shop info, connected Diagnostics devices, tool software version information. Access messages, alerts and notifications on tool Messages Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527...
  • Page 13: Front View

    Screen Power Button     USB Port 5-button Directional Input Pad NOTE: It is normal for the xMB-9640 cooling fans to continue running after the screen is turned off NOTE Rear View      ...
  • Page 14: Connections

    Insert HV Common Cable connector into port on the upper-left of the rear panel of the xMB as denoted in previous section. Connecting LV Common Cable Insert LV Common Cable connector into port on the lower-right of the rear panel of the xMB as denoted in previous section. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527...
  • Page 15: Module Balance

    IMPORTANT: Make sure to properly prepare the battery pack by following all required guidelines Refer to your documentation for complete information. Before balancing a battery module, make sure all of the external components connected to the xMB-9640 are in good working order. Parameters Discharge Charge –...
  • Page 16 Verify Module Type and target voltage, and press Next. Once the module is detected and veri- fied, press Next to start the balance procedure. Press Stop to exit. The results are displayed on the xMB screen. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527...
  • Page 17 2 – Module Balance xMB-9640 Follow on-screen guide to disconnect cables. If you have another module to balance, select ‘YES’ . Balance will be recorded as same service procedure and data will not need to be re-entered. www.midtronics.com...
  • Page 18: Module Diagnostics

    Confirm that the appropriate safety equipment is in place and press Confirm. At the Main Menu, select Module Diagnostic. Follow on screen guide to enter information and make connections to module to perform module diagnostics. Press Done to return to the Main Menu. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527...
  • Page 19: History

    4 – History xMB-9640 4 – History Use History to access the tool usage history. It displays complete and incomplete Balance or Diagnostic sessions. History At the Main Menu, tap History to display the Tool History screen. Complete Balance or...
  • Page 20: Display Settings

    IMPORTANT: All previous modifications to the original settings will be overwritten. Legal Information Displays software attribution information via the Midtronics website. The analyzer must be connected to the Internet. Check for Updates Use this function to check via the internet connection for any updates to the unit software.
  • Page 21: Date/Time Settings

    5 – Settings xMB-9640 Enable Power to Serial Bus. Check this box to enable Bar Code Scanner when Barcode Scanner is connected to unit. to return to the Shop Information screen. Date/Time Settings to access the Date/Time setting defaults. 12 Hour...
  • Page 22: Wifi

    Tap on the Printer icon to display a list of available printers on the configured WiFi and Bluetooth networks. Edit Printer Settings Printer Setup Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527...
  • Page 23: Adding A Wifi Printer

    5 – Settings xMB-9640 Delete Selected Network Configured Printers Print Test Page Adding A WiFi Printer to add a printer. Printer must be turned on and connected to WiFi.. to add a WiFi printer. Make sure the printer is on and connected to the same wireless network as the analyzer.
  • Page 24: Deleting An Address

    Select Expert Charge and/or Expert Discharge mode Once enabled, a feature will remain enable until unit is powered off. All Expert Mode features require a PIN to enable. Once enabled, the feature will appear in Main Menu. Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527...
  • Page 26 Midtronics products are warranted to be free of defects in materials and workmanship for a period of one (1) year from date of purchase. Midtronics will, at our option, repair or replace the unit with a re-manufactured unit. This limited warranty applies only to Midtronics products, and does not cover any other equipment, static damage, water damage, overvoltage damage, dropping the unit, or damage resulting from extraneous causes including owner misuse.

Table of Contents