Rectifying faults
Display machine control software version
8
Rectifying faults
All products are subject to rigorous production checks and final checks. If, despite this, something fails to
work at any time, please check the product using the following flowchart. If none of the fault rectification
procedures described leads to the correct functioning of the product, please inform your authorised dea-
ler.
8.1
Display machine control software version
Identifying the machine software is key to quick troubleshooting by the authorised service technician. The
version number is shown on the initial screen of the machine control for about 5 seconds (switch the ma-
chine off and on again) > see 4.3.4 chapter.
8.2
Error messages
The possible error numbers displayed depend on the machine series and version!
Depending on the options of the machine display, a fault is shown as follows:
Display type - machine control
Graphic display
two 7-segment displays
one 7-segment display
The possible cause of the fault is signalled by a corresponding fault number (see table). In the case of an
error, the power unit shuts down.
•
Document machine errors and inform service staff as necessary.
•
If multiple errors occur, these are displayed in succession.
•
Document machine errors and inform service staff as necessary.
•
If multiple errors occur, these are displayed in succession.
Legend for categories (reset error)
a) The error message will disappear once the error has been rectified.
b) The error message can be reset by pressing a context-dependent push-button with the
c) The error message can only be reset by switching the machine off and on again.
Error (category)
3
A, B
Tacho error
4
A
Excess temperature
5 Mains overvoltage
6 Mains undervoltage
52
Display
Possible cause
Wire feed unit interference
Permanent overload of the wire
drive.
Power source overheated
Fan blocked, dirty or defective. Check fan and clean or replace.
Air inlet or outlet blocked.
Mains voltage too high
Mains voltage too low
Remedy
Check connections (connections,
pipes).
Do not place the liner in tight radii.
Check liner for smooth movement.
Allow the switched on machine to
cool down.
Check air inlet and outlet.
Check the mains voltages and com-
pare with the power source connec-
tion voltages.
099-00L104-EW501
icon.
17.01.2022
Need help?
Do you have a question about the L1.04 - RC XQ Expert 2.0 and is the answer not in the manual?