EWM L1.04 - RC XQ Expert 2.0 Operating Instructions Manual page 54

Hide thumbs Also See for L1.04 - RC XQ Expert 2.0:
Table of Contents

Advertisement

Rectifying faults
Error messages
Error (category)
33 Error UIST
34 Electronics error
35 Electronics error
36
-Error
37 Electronics error
38 Error IIST
39 Electronics error
40 Electronics error
47
B
Bluetooth error
48
B
Ignition error
49
B
Arc interruption
50
B
Program number
51
A
Emergency stop
52 No wire feeder
53
B
No wire feeder 2
54 VRD error
55
B
Excess wire feeder cur-
rent
54
Possible cause
Voltage recording faulty
[1]
A/D-channel error
Slope error
-Conditions violated.
Temperature error
Short circuit in welding circuit
[1]
before welding.
Secondary overvoltage
I>0 error
-
no ignition at process start (au-
tomated machines).
An arc interruption occurred
during welding with an automa-
ted system.
Internal error
The emergency stop circuit of
the power source has been acti-
vated.
After switching on the automa-
ted system, no wire feeder (DV)
was detected.
Wire feeder 2 not detected.
Open circuit voltage reduction
error.
Excess current detected on wire
feed mechanism.
Remedy
Eliminate short circuit in welding cir-
cuit.
remove external sensor voltage.
Request service.
Switch the machine off and on again.
Request service.
Switch the machine off and on again.
Request service.
Switch the machine off and on again.
Request service.
Allow the switched on machine to
cool down.
Eliminate short circuit in welding cir-
cuit.
Request service.
Switch the machine off and on again.
Request service.
Request service.
Observe accompanying documenta-
tion for Bluetooth function.
Check wire feeding
Check load cable connections in
welding current circuit.
clean corroded surfaces on work-
piece before welding if necessary.
Check wire feeding.
Adjust welding speed.
Request service.
Disable the activation of the
emergency stop circuit (release pro-
tective circuit).
Check or connect the control lines of
the wire feeders;
Check the identification number of
the automated wire feeder (for 1DV:
number 1, for 2DV: each a wire fee-
der with number 1 and a wire feeder
with number 2).
Check control cable connections.
if necessary, disconnect external ma-
chine from the welding circuit.
Request service.
Do not place the liner in tight radii.
Check liner for smooth movement.
099-00L104-EW501
17.01.2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L1.04 - RC XQ Expert 2.0 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

L1.05 - rc xq expert 2.0

Table of Contents