Applied Precision WS 2120 User Manual page 95

Table of Contents

Advertisement

Working Standard
User's Guide
MEAS:MAXD:K?
Request for final result of Maximum Demand Test.
MEAS:MAXD:K:TEMP?
Request for actual (temporary) value of Maximum Demand Test.
MEAS:MAXD:WIN:BEG?
Request for timestamp of the beginning of Maximum Demand Test window.
MEAS:MAXD:WIN:END?
Request for duration of Maximum Demand Test window.
MEAS:MAXD:RES
Resets Maximum Demand Test.
MEAS:MAXD:RES?
Request for timestamp of last reset of Maximum Demand Test.
SYST:ASS:STAR
Start of Automatic Snapshots Saving Routine with predefined periodicity.
SYST:ASS:STAR?
Request for status of Automatic Snapshots Saving Routine.Answers are: 0 – not running, 1 – running.
SYST:ASS:STOP
Cease of Automatic Snapshots Saving Routine.
SYST:ASS:STAT?
Request for number of saved snapshots in currently running Snapshots Saving Routine.
SYST:ASS:MAXC {<x>}
Setting the number (x) of snapshots to be made during Automatic Snapshots Saving Routine.
SYST:ASS:MAXC?
Request for the number of snapshots to be made during Automatic Snapshots Saving Routine.
SYST:ASS:PER {<x>}
Setting the period in minutes (x) of snapshots saving occurrence during Automatic Snapshots Saving
Routine. Minimum value is 0.1 (6s) and maximum is 1440 (24h).
SYST:ASS:PER?
Request for the time period of snapshots saving occurrence during Automatic Snapshots Saving
Routine.
www.appliedp.com