Fba A Data Out - ABB ACS880 N5700 Series Firmware Manual

Position control program
Table of Contents

Advertisement

No.
Name / Range /
Selection
53

FBA A data out

53.1
FBA data out1
None
CW 16bit
Ref1 16bit
Ref2 16bit
CW 32bit
Ref1 32bit
Ref2 32bit
CW2 16bit
Other [value]
...
...
53.12
FBA data out12
Description
Selection of data to be transferred from fieldbus
controller to drive through fieldbus adapter A.
Note: 32-bit values require two consecutive parameters.
Whenever a 32-bit value is selected in a data parameter,
the next parameter is automatically reserved.
Parameters
53.01...53.12
from the fieldbus controller to the drive through
fieldbus adapter A.
None.
Control Word (16 bits)
Reference REF1 (16 bits)
Reference REF2 (16 bits)
Control Word (32 bits)
Reference REF1 (32 bits)
Reference REF2 (32 bits)
Control Word 2 (16 bits)
See
Terms and abbreviations (page
...
See parameter
53.1 FBA data
select data to be transferred
130).
out1.
Parameters 391
Def / Type
FbEq 16b / 32b
None / uint32
0
1
2
3
11
12
13
21
...
None / uint32