Outputs of the brake control logic

The mechanical brake is to be controlled by bit 0 of parameter 44.1. This bit should
be selected as the source of a relay output (or a digital input/output in output
mode) which is then wired to the brake actuator through a relay. See the wiring
example on page 101.
The brake control logic, in various states, will request the drive control logic to
hold the motor, increase the torque, or ramp down the speed. These requests are
visible in parameter 44.1.

Brake state diagram

(from any state)
1
BRAKE DISABLED
BRAKE DISABLED
BRAKE OPENING:
(from any state)
2
BRAKE CLOSED
10
8
BRAKE CLOSING
BRAKE CLOSING
DELAY
7
BRAKE CLOSING WAIT
Brake control is disabled (parameter
The brake is closed
BRAKE OPENING
3
BRAKE OPENING WAIT
6
BRAKE OPENING
3
6
6
9
44.6
(44.1
b0 = 0).
Program features 97
4
DELAY
5
BRAKE OPEN
= 0, and
44.1
b4 = 0).