Torque Reference Chain - ABB ACS880 N5700 Series Firmware Manual

Position control program
Table of Contents

Advertisement

No.
Name / Range /
Selection
26
Torque reference
chain
26.1
Torque reference to
TC
-1600.0 ... 1600.0 %
26.2
Torque reference
used
-1600.0 ... 1600.0 %
26.8
Minimum torque ref
-1000.0 ... 0.0 %
26.9
Maximum torque ref
0.0 ... 1000.0 %
26.11
Torque ref1 source
Zero
AI1 scaled
AI2 scaled
Description
Settings for the torque reference chain.
See the control chain diagrams on pages
Displays the final torque reference given to the torque
controller in percent. This reference is then acted upon
by various final limiters, like power, torque, load etc.
See the control chain diagrams on pages
This parameter is read-only.
Torque reference for torque control. For scaling, see
parameter 46.3.
Displays the final torque reference (in percent of motor
nominal torque) given to the DTC core, and comes after
frequency, voltage and torque limitation.
See the control chain diagram on page 656.
This parameter is read-only.
Torque reference for torque control. For scaling, see
parameter 46.3.
Defines the minimum torque reference. Allows for local
limiting of the torque reference before it is passed on
to the torque ramp controller. For absolute torque
limiting, refer to parameter
Minimum torque reference. For scaling, see parameter
46.3.
Defines the maximum torque reference. Allows for local
limiting of the torque reference before it is passed on
to the torque ramp controller. For absolute torque
limiting, refer to parameter
Maximum torque reference. For scaling, see parameter
46.3.
Selects torque reference source 1.
Two signal sources can be defined by this parameter
and
26.12 Torque ref2
source. A digital source selected
by
26.14 Torque ref1/2 selection
between the two sources, or a mathematical function
(26.13 Torque ref1
function) applied to the two signals
to create the reference.
26.11
0
AI
26.70
FB
...
ADD
Other
SUB
MUL
MIN
26.12
MAX
0
AI
26.71
FB
...
Other
None.
12.12 AI1 scaled value (page
12.22 AI2 scaled value (page
653
655
30.19 Minimum torque
30.20 Maximum torque
can be used to switch
26.13
Ref1
26.14
0
26.72
1
188).
190).
Parameters 297
Def / Type
FbEq 16b / 32b
and 655.
- / real32
and 656.
- / -
- / real32
- / -
-300.0 % / real32
1.
- / -
300.0 % / real32
1.
- / -
Zero / uint32
0
1
2

Advertisement

Table of Contents
loading

Table of Contents