Table of Contents

Advertisement

8.5

Binary outputs

Binary output relays: BINARY OUTPUT 1...4
Number of binary outputs
AC loading
DC loading
Switch-on current
Electrical lifetime
Pickup time
Fall back time
Bounce time
Connectors
Insulation
The diagram below shows the load limit curve for DC voltages. For AC voltages, a maximum power of
2000 VA is achieved.
Figure 31: Load limit curve for relays on the binary outputs with DC voltages
4
V
=300 V AC; I
=8 A; S
max
max
V
=300 V DC; I
=8 A; P
max
max
15 A (max. 4 s at 10 % duty-cycle)
100000 switching cycles at 230 V AC / 8 A and ohmic load
Approx. 6 ms
Approx. 3 ms
Approx. 0.5 ms
4 mm/0.16 " banana sockets
Reinforced insulation from all SELV interfaces and from power
supply
=2000 VA
max
=50 W (refer to load limit curve)
max