Download Print this page

Ametek PHANTOM Miro C321 User Manual page 52

Advertisement

Use these schematics to build custom cables at your own risk. Miswired cables
can cause serious damage to the camera, which is not covered under warranty.
Vision Research recommends only using cables supplied by Vision Research.
These pin-out diagrams refer to the connector on the camera or Miro Junction Box
body. Part numbers indicated are for the cable's connector.
MIRO C321 CAPTURE CONNECTOR
Capture port (for capture cable and MiniBoB)
12-pin Fischer Part # S-1031-Z012-130
C O N N E C T O R P I N - O U T
Vision Research, Inc. | Miro C 321/C 321J/N5/JBox 2.0 Camer a Manual
PIN
NOMENCLATURE/FUNCTION
1
2
3
TRIGGER / Isolated Input. Active low. Can be activated by a switch to
4
ground. The trigger pulse needs to be at least 3 microseconds long.
AUX2 (READY) / Isolated collector output with 1k pull-up.
5
AUX1 / Isolated collector output. Switchable between STROBE, EVENT,
6
MEMGATE and F-SYNC. Capture cable = Black
TCIN / Timecode Input can accept IRIG-B and SMPTE standards.
7
8
9
POWER / Nominal power supply voltage is +24VDC
10
11
TCOUT / Timecode Output for IRIG-B or SMPTE timecode.
12
IRIG Swings to RS-232 levels of +/- 9V. Capture cable = Blue
IOGND / Signal Ground
IOGND / Signal Ground
IOGND / Signal Ground
Capture cable = Red
Capture cable = Green
Capture cable = White
GND (reference for Pin 9)
Not used
(acceptable range is 16-36VDC)
POWER / (see Pin 10)