Download Print this page

Ametek PHANTOM Miro C321 User Manual page 18

Advertisement

Capture mode in the event of power loss. This battery operation mode is disabled in the
C321J).
Trigger mode (Default mode, always selected): This mode protects critical cines and
ensures they are saved in the event of DC power loss. The battery activates when the
camera is triggered. In the event of DC power loss, the battery will supply power to the
camera until any of the following conditions are met:
All auto save operations of Cines in RAM memory have been completed.
All Cines in RAM memory have been deleted.
The reset button on the back of the camera has been pressed.
The battery voltage has reached the full discharge limit.
The camera then automatically turns off.
CHARGING
If the battery is not fully charged (at least 8.2 volts), it will automatically charge when
the camera has DC power and is fully booted up. While charging, the camera's power
draw is 22W, and the Battery LED on the back of the camera is Blue (if not armed) or
Cyan (if armed).
The battery will not charge or stop charging under the following conditions:
A battery fault is detected. In this case, the LED
is Red.
The battery will also stop charging automatically once it is fully charged. The
LED light is off for a fully charged battery that is not armed.
A fully depleted battery requires 2.5 to 3 hours to fully charge.
Miro C321J Rear View
Vision Research, Inc. | Miro C 321/C 321J/N5/JBox 2.0 Camer a Manual
Battery Status LED
Battery Status LED
Miro C321 Rear View

Advertisement

loading

This manual is also suitable for:

Phantom miro c321jPhantom miro n5Phantom miro jbox 2.0