  • Page 1 PHANTOM HIGH-SPEED CAMERA TMX 7510/6410 USER MANUAL When it’s too fast to see, and too important not to. ®...
  • Page 2: Table Of Contents

    When it’s too fast to see, and too important not to. ® Phantom TMX 7510/6410 User Manual Camera Overview 2 Connectors 3 Network Setup & Quick Start Guide 4 On-Camera Controls & On-Screen Display 5 Working with Phantom CineMag and CineStation 6 Phantom PCC Software: - Camera Operation - Playback and Downloading...
  • Page 3: Camera Overview

    INTRODUCTION The Phantom TMX Series of high-speed cameras are designed to deliver the high frame rate performance required by many cutting edge applications, including: • Ballistics studies • Shock wave analysis • Glass crack propagation and material strain analysis TMX is available in 2 performance levels: •...
  • Page 4 DHCP router. This method eliminates the requirement to define Phantom TMX Series cameras have 2 x 3G HD-SDI outputs for use with video monitors. the PC’s dedicated camera network. Automatic DHCP is an alternative to the secondary Standard video rates up to 1080 p60 are supported.
  • Page 5: Connectors

    12-pin Fischer for signal access (Capture cable not included with camera) A complete cable connector reference and pin-out guide is available in the last section of this manual. Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 2: Connectors | 5...
  • Page 6 The latest version can be downloaded at: www.phantomhighspeed.com/PCC Gb & 10Gb ETHERNET Phantom TMX Series cameras come with standard Gigabit (Gb) Ethernet and 10-Gigabit (10Gb) Ethernet.The camera has one Ethernet port which handles both protocols. The camera will auto-negotiate the connection speed based on the computer’s network card and its IP configuration as described later in this section.
  • Page 7 Enter IP address 100.100.100.1 and Subnet 255.255.0.0. Other settings should be blank. applying to either Phantom Ethernet network connection Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 3: Net work Setup & Quick Star t | 9...
  • Page 8 After CSR and White Balance are performed, adjust settings, aperture and/or lighting to get a good exposure. A CSR must be performed after any camera settings are adjusted. Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 3: Net work Setup & Quick Star t | 11...
  • Page 9 A long press will do a fast-forward. Tap to pause. O N - C A M E R A C O N T R O L S Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 4: On-Camera Control s | 13...
  • Page 10 The Cine must be erased from the RAM to begin recording again. Playback: The camera is in ‘Playback’ mode. RAM Cines can be reviewed, edited and saved to flash. Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 4: On-Camera Control s | 15...
  • Page 11 When enabled, a black reference will be automatically performed when the camera enters ‘Capture’ mode. M E N U S Y S T E M Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 4: On-Camera Control s | 17...
  • Page 12: Phantom Pcc Software

    IP range outside of the Phantom 100.100 network. This is set using Phantom PCC software. 10-Gigabit (10Gb) IP address of the camera as assigned by Vision Research. Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 4: On-Camera Control s | 19...
  • Page 13 Sets the number of frames in a burst, which are frames that are captured to RAM with every F-Sync pulse. ‘Off’ disables burst mode. Period sets the interval between the frames in a burst. Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 4: On-Camera Control s | 21...
  • Page 14 (OSD). P H A N T O M C I N E M A G V Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 5: Working with Phantom CineMags | 23...
  • Page 15 Erase progress is indicated on the video OSD and by a progress bar in the software. Once complete, all data on the CineMag will be erased and it will be ready for recording again immediately. Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 5: Working with Phantom CineMags | 25...
  • Page 16 V or external hard drive, are performed in the ‘Play’ tab. P C C S O F T W A R E Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 6: Phantom PCC Soft ware | 27...
  • Page 17 Image Processing settings are no longer editable after saving to a format other than Cine Raw, so it is important to ensure they are set to values that produce the best looking image. Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 6: Phantom PCC Soft ware | 29...
  • Page 18 ‘Partitions’ pull-down menu. For basic camera setups, this should be set to one. after the ‘Auto’ actions have been performed. Lens Control: Available for Canon EF lenses only, for control of aperture and focus. Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 6: Phantom PCC Soft ware | 31...
  • Page 19 ‘Image Search’ can also look for images that are tagged to the camera. This is also referred to as a ‘hardware trigger.’ as ‘Event’ images. Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 6: Phantom PCC Soft ware | 3 3...
  • Page 20 Re-saving a clip in the Cine Raw format can be useful for creating sub-clips with no loss in image quality or metadata. Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 6: Phantom PCC Soft ware | 35...
  • Page 21: Signals And Programmable I/O

    Port 6 (P6) Prog I/O-Default TC Out P R O G R A M M A B L E I / O Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 7: Signal s and Programmable I/O | 37...
  • Page 22 In this context, the term ‘input’ does not represent an externally generated signal. Output signal is a frame sync pulse from the camera’s frame rate generator. A short (few Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 7: Signal s and Programmable I/O | 39...
  • Page 23: Accessories

    LENS MOUNTS time (10—500 ms or until ‘Ready’ signal goes high) will make the camera start recording, The default lens mount on a Phantom TMX Series camera is a Nikon F-mount and additional if it has an available RAM partition.
  • Page 24 The backup power source must be able to output in the 20-28V range and supply at least 8 Amps. The camera consumes maximum 395W when operated with accessories. Vision Research, Inc. | Phantom TMX Series Camer a Manual Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 9: FAQs &...
  • Page 25 RE AR VIE W M E C H A N I C A L D R A W I N G S Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 9: FAQs & Suppor t | 4 5...
  • Page 26 POWER CONNECTOR (MALE) (PRIMARY & BACKUP) Cable 3-pin Fischer Part #SS 104Z040-80 NOMENCLATURE/FUNCTION +20–28VDC CHGND / Chassis Ground GND / Power Ground Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 9: FAQs & Suppor t | 47...
  • Page 27 They should only be connected to properly grounded equipment. C O N N E C T O R P I N - O U T S Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 9: FAQs & Suppor t | 49...
  • Page 28 OCC. Select ‘Factory Defaults’ / ‘OK’. It will take approximately 20 seconds for the camera to return to an operational state. Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 9: FAQs & Suppor t | 51...
  • Page 29 Sellers and/or users need to take note of this. T: 86-21-58685111, ext. 141 C O N T A C T S U P P O R T Vision Research, Inc. | Phantom TMX Series Camer a Manual Chapter 9: FAQs & Suppor t | 5 3...
  • Page 30: Pn: Zdoc-64114-Ma-0001 Rev 1

    WWW.PHANTOMHIGHSPEED.COM The contents of this manual are subject to change without notification. PN: ZDOC-64114-MA-0001 Rev 1 Last Updated: March 2021 100 Dey Road Wayne, NJ 07470 USA +1.973.696.4500...

This manual is also suitable for:

Phantom tmx 7510Phantom tmx 6410