6 Startup

6
Startup
6.1

General Notes on Startup

The notes listed here and the startup procedure described below apply to models with electric
drive.
NOTICE
Operating voltage excessively high or incorrectly connected!
Excessively high or incorrectly connected operating voltages could cause damage to the M-126.
 Do not exceed the operating voltage range (p. 34) specified for the M-126.
 Operate the M-126 only when the operating voltage is properly connected; see "Pin
Assignment" (p. 44).
NOTICE
Unintentional motion!
The M-126 may move unintentionally when connecting it to the controller. Faulty software and
incorrect operation of the software may also cause unintended movements.
 Do not place any objects in areas where they can be caught by moving parts.
 Before connecting the M-126, check whether a macro is defined as the startup macro in
the controller and cancel the selection of the startup macro if necessary.
6.2

Starting and Operating the M-126

Requirements
 You have read and understood the general notes on startup (p. 23).
 You have installed (p. 17) the M-126 correctly.
 You have connected (p. 21) the M-126 with the controller properly.
 You have read and understood the user manual for the controller.
 The required PC software has been installed.
 You have read and understood the manual for the PC software.