Connecting The Power Supply To The M-126 - PI M-126 User Manual

Precision microtranslation stage
Table of Contents

Advertisement

5 Installation
5.6

Connecting the Power Supply to the M-126

Connecting a power adapter is only necessary for the M-126.PDx models.
Requirements
 The power cord is not connected to the power socket.
Tools and accessories
Supplied components:
If one of the components supplied for connection to the power source has to be
replaced: Use a sufficiently measured and certified replacement component. Details:
Connecting the power supply to the M-126
 Connect the Mini XLR3 connector (f) of the adapter to the Mini XLR3 panel plug of the
M-126.
 Connect the barrel connector of the adapter to the barrel connector socket of the
power supply.
 Connect the power cord to the power supply.
22
Version: 3.0.0
24 V wide-range-input power supply
Adapter for the power supply connection; barrel connector 5.5 mm x 2.1 mm to
Mini XLR3 (f)
Power cord
Power supply: Output 24 V DC, maximum output current 2 A
Power cord: Three wires, cable cross section at least 3 x 0.75 mm
maximum length 2 m
MP42E
M-126 Precision Microtranslation Stage
(3 x AWG18),
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

M-126.cg1M-126.dg1M-126.pd1M-126.pd2M-126.2s1M-126.m0

Table of Contents