PI VT-80 User Manual

PI VT-80 User Manual

Translation stage
Hide thumbs Also See for VT-80:

Advertisement

User Manual
6230-9-
Order no.
DC
SM
25 mm (xy mounted at PI)
50 mm
75 mm
100 mm
150 mm
200 mm
300 mm
Single axis
25 mm xy mounted
1
2
1
2
3
4
5
6
8
0
1
VT-80 Translation Stage
Order no. 6230-9-
User Manual
Version: 01.005
VT-80 Translation Stage 1
Date: 19.07.2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VT-80 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PI VT-80

  • Page 1 User Manual VT-80 Translation Stage 1 6230-9- Order no. VT-80 Translation Stage Order no. 6230-9- 25 mm (xy mounted at PI) 50 mm User Manual 75 mm Version: 01.005 Date: 19.07.2019 100 mm 150 mm 200 mm 300 mm Single axis...
  • Page 2 2 VT-80 Translation Stage © 2019 PI GmbH, Eschbach, Germany. The text, photographs and drawings in this manual are protected by copyright. With regard thereto, PI GmbH retains all rights. The use of any text, images and drawings is permitted only in part and only when indicating the source.
  • Page 3: Table Of Contents

    TROUBLESHOOTING PRODUCT DESCRIPTION CUSTOMER SERVICE Features and Application Area Model Overview 10. OLD EQUIPMENT DISPOSAL Product View Safety Instructions 11. EU DECLARATION OF CONFORMITY Scope of Delivery Optional Accessories www.pi.de // info@pi.de // phone:+49(0)7634-50 57 0 // fax:+49(0)7634-50 57 393...
  • Page 4: About This Document

    • Basic knowledge on servo systems, motion control concepts and The VT-80 is a laboratory device as defined by DIN EN 61010-1. It is applicable safety measures is assumed. intended for indoor use and use in an environment which is free of dirt, oil, •...
  • Page 5: General Safety Instructions

    VT-80. 2.2.2 Measures during Installation 1. Only use the VT-80 for its intended purpose, and only use it if it is in good working order. The VT-80 may be damaged by excessively long screws and wrongly 2.
  • Page 6: Measures During Start-Up

    2.2.3 Measures during Start-Up 2.2.4 Measures during Operation • • Do not put your VT-80 into operation until it is fully mounted and If noise occurs during operation of the VT-80, check the settings of the connected. servo-control parameters of your controller.
  • Page 7: Unpacking

    75 mm NOTICE 100 mm All specifications in this user manual refer only to the standard products that are included in the PI-miCos 150 mm catalog. Any special features that are different, in particular 200 mm special requests from customers, are supplied with the...
  • Page 8: Product View

    8 VT-80 Translation Stage Product View WARNING Risk of catching by rotating parts such as couplers and ball screws WARNING Risk of squeezing or crushing by moving sliders at the places illustrated. WARNING It is recommended that all persons entrusted with working...
  • Page 9 VT-80 Translation Stage 9 Technical Features RE-010 RS422 Rotary optical encoder RS-422 quadrature 4.7.1 Technical Features Encoder type HEDL rotary optical encoder Quadrature counts 2000 per revolution Signal output RS-422 Channels 2 + index Supply voltage 4.5..5.5 Current consumption, typical (Vcc = 5 V DC)
  • Page 10: Limit Switch

    10 VT-80 Translation Stage 4.7.3 Limit Switch 2SM motor, HD15 motor pin assignment with mechanical sensors HD15m Function Mechanical limit switches Motor phase A+ Motor phase A- Max. voltage (resistive load) Max. current (resistive load) Motor phase B+ Contact type...
  • Page 11: Technical Data

    VT-80 Translation Stage 11 DC-Variants 4.7.5 Technical Data www.pimicos.com // info@pimicos.com // phone:+49(0)7634-50 57 0 // fax:+49(0)7634-50 57 393...
  • Page 12: Ambient Conditions

    Ambient Conditions SM-Variants For indoor use only. • The VT-80 was calibrated at an ambient temperature of 20 °C (+/- 3 °C). • The permissible operating temperature is between + 5 °C and + 40 °C. • The permissible relative humidity is between 20% and 80%.
  • Page 13: Installation

    To guarantee the prescribed specifications (see Internet www.pimicos.com), the evenness of the mounting surface must be better than 5 µm. (Reference surface of PI measuring granite is 3 µm). Prerequisite You have read and understood the general notes on installation (see chapter 5.1).
  • Page 14: Affixing The Load

    Select the mounting position so that the existing fixing holes in the slider 1. Displace the moving platform of the VT-80 to the center position by hand of the VT-80 can be used for the additional part to be affixed.
  • Page 15: Start-Up

    General Notes on Start-Up with the corresponding hole pattern to mount a This stage must be started up with a suitable cable and the associated component onto slider of the VT-80. The controllers. maximum depth screwing into the slider plate...
  • Page 16: Maintenance

    16 VT-80 Translation Stage MAINTENANCE TROUBLESHOOTING Depending on the operating conditions and the period of use of the VT-80, If the problem that occurred with your system is not listed in the table above the following maintenance measures are required:...
  • Page 17: Old Equipment Disposal

    11. EU DECLARATION OF CONFORMITY In accordance with EU directive 2002/96/EC (WEEE), as of 13 August 2005, An EC Declaration of Conformity has been issued for the VT-80 in accordance with electrical and electronic equipment may not be disposed of in the member the following European directives: states of the EU via the municipal residual waste.