INTELLIDOX DOCKING MODULE
4.
Select a configuration file and click OK. The IntelliDoX Device Configuration dialog
box is displayed.
Click Bootloader at the bottom of the IntelliDoX Device Configuration dialog box. The
5.
IntelliDoX Selection dialog box is displayed.
6.
Click Choose File. The Choose Firmware File To Upload dialog box is displayed.
Select the downloaded file, and then click Open. The IntelliDoX Selection dialog box
is displayed.
7.
Select one or more IntelliDoX modules, and then click OK. A progress screen is
displayed while the firmware update file is automatically transferred to the selected
modules. When the transfer is complete, click OK to close the dialog box.
8.
The firmware update begins automatically when the module is idle. The LCD changes
to yellow. Installing new dock firmware. Please wait ... is displayed. Do not
deactivate the module during installation.
9.
If the module is part of a group of connected modules, then installation begins after all
of the modules in the group are idle.
10. After the update is installed, updated modules restart automatically. IntelliDoX
reboot pending. Please wait... is displayed. After a few minutes, IntelliDoX
rebooting.... The reboot takes about 5 seconds. The screen deactivates briefly
before the module restarts.
11. After the installation is complete, the LCD changes to green and Firmware update
complete is displayed.
12. Verify the version of the installed firmware.
a)
Select IntelliDoXs on the Administration menu in Safety Suite Device
Configurator software.
The Manage IntelliDoXs table is displayed. Review the module information.
b)
HONEYWELL
USER MANUAL || UPDATE FIRMWARE
PAGE 87 OF 119