3. Select the module whose outputs you want to set.
4. Check the "Control of outputs via webserver active!" box.
5. Confirm the warning notification.
Once the red dot switches to yellow, outputs can be controlled via the web
server.
AVENTICS™ PROFINET, POWERLINK, EtherNet/IP | R412018153-BAL-001-AB | English
1. To control outputs, you have to enter the desired hex value in the output data
field.
The binary value under the hex value is updated automatically.
2. Click the "Set Outputs" button.
The outputs are set to the new value.
If the unit has established a cyclic connection to a control, the dot is green and
you are unable to set output data via the web server since the outputs are being
controlled by the PLC. You can only read the output data currently set by the con-
trol.
Note that this data is not shown in real-time. The value you see in the "Output
Data" area may have changed since the website was last refreshed.