2. Use a web browser to exchange data between the PC and the AES module
web server. In the address bar, enter the IP address of the AES module.
The module IP address is the same as the IP address for PROFINET IO commu-
nication.
You are now connected to the web server.

3.2 POWERLINK

Requirement:
In your valve system, you use an AES bus coupler for POWERLINK (R412018226).
Risk due to misuse!
The web server in the AES module is a tool for the implementation phase and
to update the module software.
1. Make sure that the machine is in a safe state while you are working with the
web server.
2. Never use the web server for permanent monitoring.
To establish a connection with the AES module web server, you can either con-
nect the AES module directly to a PC or to the fieldbus.

3.2.1 Connecting the AES module to the PC

To connect the AES module to a PC, you need an Ethernet cable with the follow-
ing connections:
• RJ45 plug for connection to the computer
• M12 plug (male), D-coded, for connection to the bus coupler
In addition, you need a power supply line with an M12, A-coded plug (female).
Refer to the bus coupler system description for more information on the M12
plug assignment.
1. Set your computer's IP address to a free IP address and the subnet of the
POWERLINK system.
AVENTICS™ PROFINET, POWERLINK, EtherNet/IP | R412018153-BAL-001-AB | English
NOTICE
2. Connect the AES module to your computer's EtherNet interface and switch
the AES module on.
The "S/E" LED flashes quickly in green.
3. Use a web browser to exchange data between the PC and the AES module
web server. In the address bar, enter the IP address of the AES module. The
first three bytes of the IP address are defined by the POWERLINK subnet and
the fourth byte by the node ID of the AES module (192.168.100.POWERLINK
address).
You are now connected to the web server.

3.2.2 Connecting the AES module to the POWERLINK network

Error due to unqualified personnel!
Connection and configuration errors result in disruptions in POWERLINK com-
munication.
Connection and configuration may therefore only be carried out by quali-
u
fied personnel (see g 2.4. Personnel qualifications ).
Requirement:
• You need access data. In the following example, the PLC is configured for ac-
cess.
NOTICE
15