Malfunction
Teacher screen shows no
display.
's Teacher screen cannot
be sent to all participants.
Monitors of all or some
participants go dark.
Cause
Power supply of the parti-
cipant box of the teacher
station is defective. Local
operation is usually pos-
sible even without a power
supply.
Teacher key is not as-
signed correctly.
"BUS in" and "BUS out"
connectors on participant
box have been inter-
changed or participant box
or patch cable is defective
(only if teacher receives no
image).
Teacher key is not as-
signed correctly.
"BUS in" and "BUS out"
connectors on participant
box have been inter-
changed or participant box
or patch cable is defective.
Instructions for use KaVo EDUnet ULTRA HD
Remedy
▶ Check power supplies and replace according to
need.
▶ Reassign the teacher key.
See also:
2 5.3 Assign the teacher key, Page 23
▶ Use installation plan to identify the affected parti-
cipant boxes (dark screen).
▶ Check the "BUS in" and "BUS out" connectors.
ð
If the connection if active, the LED of the "BUS in"
connector is on. If the connectors of a participant
box have been interchanged, there must be at
least one other participant box whose connectors
have also been interchanged.
▶ If all connectors are plugged-in correctly, replace
participant box or patch cable.
▶ If the connectors have been interchanged, check
all participant boxes and switch connectors as
needed.
▶ Reassign the teacher key.
See also:
2 5.3 Assign the teacher key, Page 23
▶ Send participant screen "To all".
ð
The sender screen is displayed on at least one
other participant screen.
▶ Use installation plan to identify the pertinent parti-
cipant boxes.
ð
The participant work-stations to which the sender
screen is not transmitted are all situated in se-
quence.
▶ Check the "BUS in" and "BUS out" connectors.
ð
If the connection if active, the LED of the "BUS in"
connector is on.
ð
If the connectors of a participant box have been in-
terchanged, there must be at least one other parti-
cipant box whose connectors have also been inter-
changed.
▶ If all connectors are plugged-in correctly, replace
participant box or patch cable.
▶ If the connectors have been interchanged, check
all participant boxes and switch connectors as
needed.
45 / 52