Advertisement

Quick Links

Operating Instruction
Vakuum-Mixer EWL 5837
1.000.8424 DE
1.000.9672 GB
1.000.9677 US
KaVo Elektrotechnisches Werk GmbH
Wangener Straße 78
D-88299 Leutkirch
Tel.: 0 75 61 / 86-0 • Fax: 0 75 61 / 86-22 2

Advertisement

Table of Contents
loading

Summary of Contents for KaVo EWL 5837

  • Page 1 Operating Instruction Vakuum-Mixer EWL 5837 1.000.8424 DE 1.000.9672 GB 1.000.9677 US KaVo Elektrotechnisches Werk GmbH Wangener Straße 78 D-88299 Leutkirch Tel.: 0 75 61 / 86-0 • Fax: 0 75 61 / 86-22 2...
  • Page 3: Table Of Contents

    Care of the unit ............................6 A 8.1 Cleaning ..............................6 A 8.2 Maintenance ............................6 A 8.3 Repairs ..............................6 Technical data ..............................7 A 9.2 Vacuum Mixer EWL 5837 ........................7 Warranty information ............................7 Accessories ..............................8 Spare parts ..............................8 Spare parts ..............................9 EWL 5837...
  • Page 4: A 1 Features

    A 1 Features KaVo EWL vacuum mixers serve not only for the mixing of all types of plaster, investment materials and silicones, but also for special techniques in dental technology such as the hydration of models. They are provided with separate drive systems for generation of vacuum, and the stirring mechanism. The stirring mechanism can be switched on and off by a time-controller at any time, without disturbing the vacuum.
  • Page 5: A 3 Applications

    Before putting the unit into operation check if the security plate on the underside of the unit has been turned 90°, and projects beyond the housing. Tighten the screws again to prevent unwanted movement. EWL 5837...
  • Page 6: A 5 Preparing For Operation

    • The compressed air supply must be checked (see also A 4.2) • If the unit is not to be used for a lengthy period, turn off the compressed air, and disconnect the machine from the electrical supply. EWL 5837...
  • Page 7: A 6 Operating The Unit

    - Vibrator arm and rubber ball will vibrate. - Hold impression tray (or small impression) against the ball, and fill up with mixed material (plaster, etc.) in small portions. Thereby, even small jobs can be accomplished using the unit. EWL 5837...
  • Page 8: A 7 Troubleshooting

    • After changing, firmly screw in the bolt again – don`t forget the O-ring! A 8.3 Repairs Service or repairs of the unit must be carried out only by trained technical personnel. Modifications by others, and use of unauthorized parts, invalidates the Product Liability. Use only original spare parts. EWL 5837...
  • Page 9: A 9 Technical Data

    Within the scope of the current Delivery and Payment Conditions, KaVo EWL warrants the unit to be free from malfunctions, defects in both materials and workmanship for a period of 6 months from the date of purchase. At the end of this warranty period, KaVo provides a further 6-months guarantee for faults arising, which can be traced back to deficiencies in materials or the manufacturing process.
  • Page 10: Accessories

    1.001.2124 Bowl, extra small complete 75 ml 1.001.2088 Bowl, small complete 200 ml 1.001.2089 Bowl, large complete 600 ml 1.001.2090 Bowl, extra large complete 900 ml 1.001.2121 Vacuum hydration bowl 600 ml 1.001.2122 Bowl, medium complete 350 ml EWL 5837...
  • Page 11: Spare Parts

    EWL 5837 SPARE PARTS Spare parts 1.001.2020 1.001.2064 1.001.2063 1.001.2062 1.001.2195 1.001.2056 1.001.2065 1.001.2186 1.001.2057 1.001.2019 1.001.2055 EWL 5837...

Table of Contents