Summary of Contents for KaVo ERGOcam One

  • Page 1 Instructions for use ERGOcam One...
  • Page 2 Distributed by: Manufacturer: KaVo Dental GmbH Kaltenbach & Voigt GmbH Bismarckring 39 Bismarckring 39 D-88400 Biberach D-88400 Biberach Phone +49 (0) 7351 56-0 www.kavo.com Fax +49 (0) 7351 56-1488...
  • Page 3: Table Of Contents

    Instructions for use ERGOcam One Table of contents Table of contents 1 User Notes................................ 5 1.1 User guide .............................. 5 1.1.1 Abbreviations .......................... 5 1.1.2 Symbols ............................ 5 1.1.3 Target group .......................... 5 1.2 Service.............................. 5 1.2.1 Technical customer service ...................... 6 1.3 Terms and conditions of warranty...................... 6 1.4 Transportation and storage........................ 6...
  • Page 4 Instructions for use ERGOcam One Table of contents 6.3 Maintenance ............................ 25 7 Troubleshooting.............................. 26 8 Information about electromagnetic compatibility in accordance with EN60601-1-2 ........ 27 4 / 30...
  • Page 5: User Notes

    Instructions for use ERGOcam One 1 User Notes | 1.1 User guide 1 User Notes 1.1 User guide Requirement Read these instructions prior to first use to avoid misuse and prevent damage. 1.1.1 Abbreviations Abbre- Explanation viation Instructions for use...
  • Page 6: Technical Customer Service

    Claims from this warranty can only be asserted when the transfer form (copy) belong- ing to the product has been sent to KaVo, and the original can be presented by the op- erator or user.
  • Page 7: Information On The Packaging: Storage And Transportation

    Art. 28). Outside Germany Note KaVo shall not be held liable for damage arising from transportation. The shipment must be checked on arrival. If the packaging is visibly damaged on delivery, please proceed as follows: 1. The recipient of the package must record the loss or damage on the delivery re- ceipt.
  • Page 8 Instructions for use ERGOcam One 1 User Notes | 1.4 Transportation and storage The symbols printed on the outside are for transportation and storage, and have the following meaning: Transport upright with the arrows pointing upwards! Fragile - protect against impact!
  • Page 9: Safety

    KaVo product for the intended purpose must be applied and followed. This KaVo product is intended for use in dentistry only. Any other type of use is not permitted.
  • Page 10 This KaVo product may only be repaired at the KaVo factory Warthausen. Regular performance of maintenance and safety checks is essential for the permanent assurance of the operating and functional safety of the KaVo product and for the pre- vention of damage and hazards.
  • Page 11 Instructions for use ERGOcam One 2 Safety | 2.2 Purpose – Proper use Note KaVo cannot guarantee the compliance of accessories, cables, and other compon- ents not supplied by KaVo with the EMC requirements of IEC 60601-1-2 (DIN EN 60601-1-2). Disposal Note...
  • Page 12: Product-Specific

    Instructions for use ERGOcam One 2 Safety | 2.3 Safety instructions 2.2.2 Product-specific The intraoral camera serves the generation of video signals for visualisation e.g. the oral cavity of a patient via a suitable display medium. The generated data is used for the patient´s information and to support the diagnosis.
  • Page 13: Protective Equipment

    Instructions for use ERGOcam One 2 Safety | 2.4 Protective equipment CAUTION Danger to health due to wrong diagnosis as a result of a camera image. The camera is not a diagnostic instrument! Danger of incorrect treatment. ▶ Do not use the camera as a diagnostic instrument.
  • Page 14: Description Of The Product

    Instructions for use ERGOcam One 3 Description of the product | 3.1 System components 3 Description of the product 3.1 System components ① Deflection prism ② Exposure window ③ Camera head ④ Camera handpiece with connecting cable ⑤ Trigger ⑥ Interface of the treatment unit...
  • Page 15: Ids And Labels

    Instructions for use ERGOcam One 3 Description of the product | 3.2 IDs and labels 3.2 IDs and labels 3.2.1 Camera handle ① Product name ② Company logo of the manufacturer ③ SN for serial number ④ Mat. number ⑤ Disposal instructions ⑥...
  • Page 16 Instructions for use ERGOcam One 3 Description of the product | 3.3 Technical Specifications Image Detector Colour sensor 1/4“ CMOS Pixel PAL 1276 (H) x 769 (V) Camera module Type USB 2.0 Illumination 1 LED Illumination intensity at 10 mm distance...
  • Page 17: System Requirements

    Instructions for use ERGOcam One 3 Description of the product | 3.4 System requirements 3.4 System requirements CPU cycle min. 2 GHz Memory min. 1 GB Graphic requirements min. 24 bit / 1024x768 Interface USB 2.0 17 / 30...
  • Page 18: Commissioning

    Note A PC is required for the operation of the camera (not included in the delivery) Note The ERGOcam One may only be used on equipment which at least fulfil the stand- ard EN DIN ISO 60950. Note The distance between the PC and camera cable (floor terminal box) must not ex- ceed 10 m.
  • Page 19: Carry Out A Safety Check

    Verification of correct installation: ▪ A further USB input device is displayed under device manager (human interface device) following connection of the camera. ▪ A device "ERGOcam One" is displayed in the device manager under image pro- cessing device. Note An additional software e.g.
  • Page 20: Use Of Disposable Protective Covers

    Instructions for use ERGOcam One 4 Commissioning | 4.3 Use of disposable protective covers 4.3 Use of disposable protective covers Remove the disposable protective cover WARNING Risk of infection due to soiled or contaminated camera Infection. ▶ When using the camera, always use a disposable protective cover.
  • Page 21 Instructions for use ERGOcam One 4 Commissioning | 4.3 Use of disposable protective covers Note For the pictures of the system to be optimum, there may be no air between the clear view window of the single-use cover and the exposure window of the camera.
  • Page 22: Operation

    Instructions for use ERGOcam One 5 Operation | 5.1 Switching the camera on and off 5 Operation CAUTION Danger to health due to wrong diagnosis as a result of a camera image. The camera is not a diagnostic instrument! Danger of incorrect treatment.
  • Page 23: Operating Mode

    Instructions for use ERGOcam One 5 Operation | 5.4 Operating mode 5.4 Operating mode The camera presents a sharp image at a distance of 10 - 25 mm (camera - tooth). It is designed for the imaging of a tooth. Imaging of a dental arch or extraoral images are not possible.
  • Page 24: Preparation Methods

    Instructions for use ERGOcam One 6 Preparation methods | 6.1 Cleaning 6 Preparation methods Note The camera handle cannot be sterilised or disinfected with heat. 6.1 Cleaning Note Disinfect the camera before cleaning. Disinfect after cleaning if necessary. 6.1.1 Exterior cleaning by hand CAUTION Damage to camera due to improper cleaning.
  • Page 25 Instructions for use ERGOcam One 6 Preparation methods | 6.3 Maintenance CAUTION Damage to the camera due to improper disinfection. Irreversible destruction of the camera. ▶ Disinfect with wipes only, do not use disinfectant sprays. ▶ Do not immerse the camera in liquids.
  • Page 26 Instructions for use ERGOcam One 7 Troubleshooting 7 Troubleshooting Note If malfunctions cannot be located or eliminated using this troubleshooting guide, a technician trained by KaVo must be commissioned to eliminate the problem. Malfunction Cause Remedy ▶ Check by technician is necessary.
  • Page 27 Instructions for use ERGOcam One 8 Information about electromagnetic compatibility in accordance with EN60601-1-2 8 Information about electromagnetic compatibility in accordance with EN60601-1-2 See also: 2 For "Specific details concerning electromagnetic compatibility in accordance with EN 60601-1-2", see the instructions for use of the respective treatment centre...