9.1 Emergency power supply
NOTE
Emergency supply if totally discharged
If you ignore the battery warnings, the SmartLocker AX may fail to open. If
this happens the battery compartment is no longer accessible. You may
connect an emergency power supply for changing the batteries.
1. Turn the screw at the reader's bottom clockwise to push it in (0.9 mm
hexagon key).
2. Remove the cover.
3. Connect a power supply to the micro USB connector (e.g. USB plug,
USB charger, powerbank).
4. Present an ID medium.
SmartLocker AX opens.
9
5. Open the locker, remove the micro USB cable and reassemble the
reader.