Model Cls1000-Ai; Pin Assignment; Analog Output; Switching Output - MICRO-EPSILON optoCONTROL CLS1000 Operating Instructions Manual

Table of Contents

Advertisement

Installation and Assembly
4.5.4

Model CLS1000-AI

4.5.4.1

Pin Assignment

Pin Signal/assign-
ment
1
V
+
2
OUT2
3
GND
4
OUT1
5
TRG
1
1
1) Only for controller CLS1000-AI-xx-T with trigger function
Alternatively, for the model without trigger function, an angled signal/power supply cable PC1000/90-5 with a connector
angled at 90° (or open ends) is available with shielding.
4.5.4.2

Analog Output

The sensor supplies a current output of 0 ... 20 mA or 4 ... 20 mA.
Analog output properties
Current output
Fig. 16 Analog output switching
4.5.4.3

Switching Output

The switching variants of the switching output (PP/PNP/NPN) as well as the switching thresholds can be changed and
adjusted using the operating menu.
The switching behavior (NPN, PNP , push-pull (PP)) of the switching output depends on the programming.
0/4 mA
Q
Fig. 17 Circuit for CLS1000-AI
optoCONTROL CLS1000
Description
Comments, circuitry
12 ... 30 VDC
Supply voltage
I
< 50 mA
max
0 ... 20 mA / 4 ... 20 mA
Analog output
switchable ≤ R
max 500 Ohm
Ground for supply, switch-
Ground
ing output Q and analog
output and trigger (IN)
V
max. 12 ... 30 VDC,
+
I
= 100 mA, Signal level
max
Switching out-
depends on supply volt-
put Q1
age, switching behavior
programmable: NPN, PNP ,
PP
max. 30 VDC; input current
Trigger (IN)
1
I
= < 1 mA
max
0 ... 20 mA or 4 ... 20 mA;
switchable ≤ R
max. 500 Ohm
L
1
Brown
20 mA
2
White
Black
4
3
Blue
PC1000-x
cable color
Brown
White
L
Blue
1
Black
Gray
1
Sensor
PC1000-x
pin
cable color
2
White
3
Blue
V
+
U Analog
PP / PNP / NPN
GND
2
2
1
3
1
4
Fig. 14 4-pin
Fig. 15 5-pin cable
cable socket,
socket,
view of solder
view of solder side
side
Comments
Analog output
Ground
3
5
4
1