How To Select A Pulselength; How To Change The Preset Pulselength - Furuno FAR-2228-BB Operator's Manual

Hide thumbs Also See for FAR-2228-BB:
Table of Contents

Advertisement

1. OPERATIONAL OVERVIEW
1.18

How to Select a Pulselength

The pulselength in use is indicated on the PULSE button of the InstantAccess bar
at the top-left of the screen.The table below shows the indications and their meaning.
Appropriate pulselengths are preset to individual range scales and function keys. If
you are not satisfied with the current pulselength settings, you can change them as
shown in the procedure below.
1.18.1
How to select a pulselength
The pulselength can be changed using the procedure below.
1. Place the cursor in the [PULSE] box at the top left corner of the screen.
2. Left-click to decrease, right-click to increase the pulselength; or spin the scroll-
wheel to cycle through pulselengths.
The order in which the pulselengths are cycled is shown in the table below. "*" in-
dicates the default preset for each range setting.
Range
0.5 NM
0.75 NM
1.5 NM
3 NM
Note: Available pulselengths are restricted depending on the range.
1.18.2

How to change the preset pulselength

To change the preset pulselength for a range setting, follow the procedure below.
1. Open the menu.
2. Select [1 ECHO].
3. Select [2 CUSTOMIZED ECHO].
Note: You can also access the [CUSTOMIZED
ECHO] menu from the on-screen box. Place the
cursor on the [PICTURE] indication in the date
box at the top-left of the screen, then right-click.
4. Select [9 PULSE LENGTH].
5. Select the desired range, then select the re-
quired pulselength.
6. Close the menu.
1-28
[ PULSE ] button
PULSE
L
Current pulse length appears here.
(S1, S2, M1, M2, M3, L)
(PULSE) indication
S1*, S2
S1*, S2, M1
S1*, S2, M1, M2
S2*, M1, M2, M3
Range
(PULSE) indication
6 NM
M1, M2*, M3, L
12 NM
M1, M2, M3*, L
24 NM
M2, M3, L*
,

Hide quick links:

Advertisement

Table of Contents
loading