ALR
ALF
Alert ID
Alert ID
-
52001,46 HW STATUS NOTICE Caution
Remedy: Press the ALARM ACK key. Have a qualified technician check the RF-Converter.
-
52001,47 HW STATUS NOTICE Caution
Remedy: Press the ALARM ACK key. Have a qualified technician check the HPA board.
-
52001,48 HW STATUS NOTICE Caution
Remedy: Press the ALARM ACK key. Have a qualified technician check the HPA board.
-
52001,51 HW STATUS NOTICE Caution
Remedy: Press the ALARM ACK key. Have a qualified technician check the HPA board.
-
52001,52 HW STATUS NOTICE Caution
Remedy: Press the ALARM ACK key. Have a qualified technician check the antenna.
83
52002,01 HW STATUS ERROR
Remedy: Press the ALARM ACK key. Have a qualified technician check the processor unit.
84
52002,02 HW STATUS ERROR
Remedy: Press the ALARM ACK key. Have a qualified technician check the processor unit.
85
52002,03 HW STATUS ERROR
Remedy: Press the ALARM ACK key. Have a qualified technician check the processor unit.
86
52002,04 HW STATUS ER-
Remedy: Press the ALARM ACK key. Have a qualified technician check the processor unit.
87
52002,05 HW STATUS ER-
Remedy: Press the ALARM ACK key. Have a qualified technician check the processor unit.
APPENDIX 3 ALERT CODES, MESSAGES & MEANINGS
Alert title
6
ROR*
6
ROR*
Priority &
Category
Message: "RF-CONV:INTPUT SIG-
Cat: B
NAL LEVEL ERROR"*
Meaning: Signal input to the RF Con-
verter is outside rating.
Message: "HPA:OUTPUT SIGNAL
Cat: B
LEVEL ERROR"*
Meaning: Signal output from the HPA
board is outside rating.
Message: "HPA:OUTPUT PEAK CUR-
Cat: B
RENT ERROR"*
Meaning: Peak current detected in the
signal output from the HPA board.
Message: "HPA:TEMP HIGH"*
Cat: B
Meaning: Excessively high tempera-
ture detect on the HPA board.
Message: "VSWR ERROR"*
Cat: B
Meaning: Abnormal VSWR detected
by the RF Converter.
Warning
Message: "RPU FAN1 NO ROTA-
Cat: B
TION"
Meaning: Fan1 in the processor unit is
stopped or disconnected.
Warning
Message: "RPU FAN2 NO ROTA-
Cat: B
TION"
Meaning: Fan2 in the processor unit is
stopped or disconnected.
Warning
Message: "RPU FAN3 NO ROTA-
Cat: B
TION"
Meaning: Fan3 in the processor unit is
stopped or disconnected.
Warning
Message: "RPU FAN (RP) NO ROTA-
Cat: B
TION"
Meaning: The RPU fan on the RP
board, in the processor unit, is stopped
or disconnected.
Warning
Message: "RPU RP HW ERROR"
Cat: B
Meaning: The RP board has stopped
working.
Alert description
5
5
5
5
5
AP-19