How To Acquire And Track Targets; How To Manually Acquire A Target - Furuno FAR-2228-BB Operator's Manual

Hide thumbs Also See for FAR-2228-BB:
Table of Contents

Advertisement

3. TARGET TRACKING (TT)
4. Select [2 TT SELECT], then select the acquisition condition.
Your selection here changes how many targets can be acquired, both automati-
cally and manually.
[MANUAL 100]
[MANUAL 75 • AUTO 25] 25 targets automatically, 75 targets manually
[MANUAL 50 • AUTO 50] 50 targets automatically, 50 targets manually
[MANUAL 25 • AUTO 75] 75 targets automatically, 25 targets manually
[AUTO 100]
5. Close the menu.
Note: When the menu-set number of automatically acquired targets have been ac-
quired, the Alert "TT TARGET FULL(AUTO)" appears in the [Alert] box.
3.5

How to Acquire and Track Targets

This radar can automatically acquire and track a maximum of 100 targets.
A target just acquired automatically is marked with a dashed circle and a vector ap-
pears within one minute to indicate the target's motion trend. Within three minutes, the
initial tracking stage is finished and the target becomes ready for stable tracking. At
this time, the dashed circle changes to a solid circle.
At acquisition
3.5.1

How to manually acquire a target

Acquire a target from the Control Unit (RCU-014)
Use the trackball to place the cursor on the target you want to acquire, then press the
ACQ key.
Acquire a target by the trackball module
1. When the target to acquire and the AIS symbol overlap one another, right-click the
operational display area to show the [CURSOR MENU] then select [TT TARGET
DATA/ACQ] to acquire the target.
2. Place the cursor on the target to acquire then left-click.
The plotting symbol is drawn by a dashed circle during the initial acquisition stage. A
vector appears approximately one minute after acquisition. The vector indicates the
motion trend of the target. If the target is consistently detected for three minutes, the
plotting symbol changes to a solid circle. If acquisition fails, the target symbol blinks.
3-4
Menu setting
100 targets manually, auto acquisition not available
100 targets automatically, manual acquisition not avail-
able
Within 1 min. after acquisition
Acquisition condition
Vector
Stable tracking

Hide quick links: