Mirroring (RAID 1)
Writes duplicate data on to a pair of drives while reads are performed in parallel. ATA RAID 1 is fault
tolerant because each drive of a mirrored pair is installed on separate IDE channels. If one of the
mirrored drives suffers a mechanical failure (e.g. spindle failure) or does not respond, the remaining
drive will continue to function. This is called Fault Tolerance. If one drive has a physical sector error,
the mirrored drive will continue to function.
RAID 1 (Mirroring)
TM
On the next reboot, the FastBuild
utility will display an error in the array and recommend to replace
the failed drive. Users may choose to continue using their PC, however Promise recommends
replacing the failed drive as soon as possible. See Chapter 4 for a functional description.
Due to redundancy, the drive capacity of the array is half the total drive capacity. For example, two
1GB drives that have a combined capacity of 2GB would have 1GB of usable storage. With drives of
different capacities, there may be unused capacity on the larger drive.