Using Standalone Operation; Setting A Static Color Manually - SGM Q-10 User Manual

Hide thumbs Also See for Q-10:
Table of Contents

Advertisement

Q-10 Connection diagram
100- 277V AC
50-60 Hz
1000W
XLR pin out
DATA
GND
DATA -
DATA +

Using standalone operation

Standalone operation is not running when the fixture is connected to a control device, but when it is pre-programmed with a series of
up to 24 scenes, playing continuously in a loop. Up to three stand-alone programs can be defined and run from the menus, and one of
the programs can be set to run by default whenever the fixture is powered on.
Each of the three available stand-alone programs contains 24 user-definable
scenes with its own RGB and shutter settings.
Each scene has a definable fade-in time for the transition from one color to the
next, and a wait (static) time of up to 120 minutes and 59 seconds.
To define a stand-alone program, press ENTER → MANUAL → EDITOR.
The standalone mode of the fixture's startup is enabled by selecting:
ENTER → SETTINGS → STARTUP MODE → SELECT STARTUP MODE →
STANDALONE.
To select the fixture's startup program, press:
ENTER → SETTINGS → STARTUP MODE → STARTUP PROGRAM.
The chosen program will run its length cyclically whenever the fixture is
powered on.
To run an internal program, go to:
ENTER → MANUAL → RUN PROGRAM.
To stop an active internal program, go to:
ENTER → MANUAL → STOP PROGRAM.
Please note: In POI versions, configuring the fixtures can only be done through RDM.

Setting a static color manually

The Q-10 can be configured to display a predefined and static color.
To set up a static color select ENTER → MANUAL → QUICK COLOR.
Note that, once the MANUAL → QUICK COLOR settings are changed, the fixture is set, by default, to automatically start in quick color
mode whenever it is powered on. This can be reset through the menu SETTINGS → STARTUP MODE → SELECT STARTUP MODE.
The current quick color program can always be stopped by going to:
ENTER → MANUAL → STOP PROGRAM
See "Control menu" on page 13 for detailed information about the manual menu.
Please note: In POI versions, configuring the fixtures can only be done through RDM.
1
5 PIN XLR
Figure 11: Q-10 connection diagram (see page 17 for POI version)
2
Max. 32 units/DMX line
100- 277V AC
50-60 Hz
1000W
Figure 12: Standalone operation
XX
100- 277V AC
50-60 Hz
1000W
120 Ohm +/- 5%
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q seriesQ-10 poiQ-7

Table of Contents