Angle indicator
The Q-10 comes with a scale function, which eases the adjustment to the tilt desired.
The angle indicator in the wheel shows the current angle of inclination.
NOTE: In POI versions, SGM provides a POI Spanner with a pig-nose key for tilt adjustment. Either use the large or the small
pig-nose key, depending on the type of fixture. See page 16 to know more about the tilt lock in Q-10 POI.

Connecting AC power

The fixture must be grounded/
The Q-10 Series can operate on any 100–277 V, 50/60 Hz AC mains power supply.
earthed and be able to be isolated
from AC power. The AC power
Connect a Q-10 standard to AC power using the supplied cable with a powerCON TRUE1 connector,
supply must incorporate a fuse or
or similar with a maximum of 20 A, to ensure the correct ingress protection (IP-rating).
curcuit breaker for fault protection.
The fixture must be grounded/earthed and able to be isolated from AC power. The AC power supply
must incorporate a fuse or circuit breaker for fault protection.
The power cable color coding is given in figure 7:
The fixture must be grounded/
earthed and be able to be isolated
Connect the black wire to live
from AC power. The AC power
Connect the white wire to neutral
supply must incorporate a fuse or
Connect the green/yellow wire to ground (earth)
circuit breaker for fault protection.
For a temporary outdoor installation, the mains cable must be
fitted with a grounded connector intended for exterior use. For
permanent installations, have a qualified electrician to wire the mains cable directly to a suitable branch circuit. The junction's ingress
protection (IP) rating must be suitable for the location. Always use a junction box with a proper IP class suitable for the environment.
When installing standard type C circuit breakers there will be no limitations due to the fixture in-rush current.
For assistance with alternative configurations, contact your SGM representative.
NOTE: In POI versions, SGM supplies a power cable with bare ends. Connect the fixture to power by mounting a power
connector to the bare ended mains cable. Please refer to page 16-17 for connecting AC power in POI fixtures.
After connecting the Q-10 to power, run the on-board test by selecting TEST → AUTOMATED TEST in the menu, to ensure that the
fixture and each LED are functioning correctly. POI versions have to be tested through RDM.
PLEASE NOTE!
The protective caps must be securely mounted on any unused DMX connectors, in order to maintain the ingress protection (IP-rating)
CAUTION!!
Do not connect the fixture to an electrical dimmer system, as doing so may cause damage.

Configuring the device

The Q-10 can be set up by using the control panel and OLED multiline display on the fixture's head or through RDM.
Please note: In POI versions there is no display mounted in the fixture. The adjustments are made through RDM.
See page 15 for more information.
The OLED display is the human interface of the fixture, as it displays the current status and menu of the fixture. The display panel
can be used to configure individual fixture settings, check the fixture's wireless status, confirm the firmware version, and read error
messages. The complete list of the menu and all commands available are listed in "Control Menu" on page 13.
Before turning on the Q-10, make sure the power in cable is properly connected. To turn off the device, simply disconnect power in
cable. When the fixture is powered on, it boots and resets before displaying the currently selected operating mode and the DMX start
address. Navigate through the menus and options using the arrow buttons, and select items using the ENTER button.
8
Wire
Color
Black
White
green/yellow
8
DMX
6CH MODE
(14)
Figure 8: OLED display and control panel
Symbol
Conductor
L
live
N
neutral
or
ground (earth)
Wire
Color
Black
White
green/yellow
Figure 7: Connecting AC Power
ESC
ENTER
Figure 6: Q-10 Power cable
Symbol
Conductor
L
live
N
neutral
or
ground (earth)